File Download

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

하준형

Ha, Junhyoung
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Pediatric Airway Stent Designed to Facilitate Mucus Transport and Atraumatic Removal

Author(s)
Ha, JunhyoungMondal, AbhijitZhao, ZhanyueKaza, Aditya K.Dupont, Pierre E.
Issued Date
2020-01
DOI
10.1109/TBME.2019.2910551
URI
https://scholarworks.unist.ac.kr/handle/201301/87273
Fulltext
https://ieeexplore.ieee.org/document/8688439/
Citation
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, v.67, no.1, pp.177 - 184
Abstract
Objective: The goal was to develop a pediatric airway stent for treating tracheobronchomalacia that could be used as an alternative to positive pressure ventilation. The design goals were for the stent to allow mucus flow and to resist migration inside the airways, while also enabling easy insertion and removal. Methods: A helical stent design, together with insertion and removal tools, is presented. A mechanics model of stent compression is derived to assist in selecting stent design parameters (pitch and wire diameter) that provide the desired amount of tracheal support, while introducing the minimal amount of foreign material into the airway. Worst-case airway area reduction with stent support is investigated experimentally using a pressurized tracheal phantom matched to porcine tracheal tissue properties. The stent design is then evaluated in a porcine in vivo experiment. Results: Phantom testing validated the mechanics model of stent compression. In vivo testing demonstrated that the stent was well tolerated by the animal. Since the helical design covers only a small portion of the epithelium, mucus transport through the stented region was minimally impeded. Furthermore, the screw-like stent resisted migration, while also providing for atraumatic removal through the use of an unscrewing motion during removal. Conclusion: The proposed stent design and tools represent a promising approach to prevent airway collapse in children with tracheobronchomalacia. Significance: The proposed technology overcomes the limitations of existing airway stents and may provide an alternative to maintaining children on a ventilator.
Publisher
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
ISSN
0018-9294
Keyword (Author)
Tracheobronchomalaciaairway stent
Keyword
INFANTSTRACHEOBRONCHOMALACIAPRESSURECHILDRENRISKCT

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.