File Download

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

조형준

Cho, Hyungjoon
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Improved laminar specificity and sensitivity by combining SE and GE BOLD signals

Author(s)
Han, SohyunEun, SeulgiCho, HyungjoonUludaq, KamilKim, Seong-Gi
Issued Date
2022-12
DOI
10.1016/j.neuroimage.2022.119675
URI
https://scholarworks.unist.ac.kr/handle/201301/59749
Citation
NEUROIMAGE, v.264, pp.119675
Abstract
The most widely used gradient-echo (GE) blood oxygenation level-dependent (BOLD) contrast has high sensitivity, but low specificity due to draining vein contributions, while spin-echo (SE) BOLD approach at ultra-high magnetic fields is highly specific to neural active sites but has lower sensitivity. To obtain high specificity and sensitivity, we propose to utilize a vessel-size-sensitive filter to the GE-BOLD signal, which suppresses macrovascular contributions and to combine selectively retained microvascular GE-BOLD signals with the SE-BOLD signals. To investigate our proposed idea, fMRI with 0.8 mm isotropic resolution was performed on the primary motor and sensory cortices in humans at 7 T by implementing spin- and gradient-echo (SAGE) echo planar imaging (EPI) acquisition. Microvascular-passed sigmoidal filters were designed based upon the vessel-size-sensitive ΔR2*/ΔR2 value for retaining GE-BOLD signals originating from venous vessels with ≤ 45 μm and ≤ 65 μm diameter. Unlike GE-BOLD fMRI, the laminar profile of SAGE-BOLD fMRI with the vessel-size-sensitive filter peaked at ∼ 1.0 mm from the surface of the primary motor and sensory cortices, demonstrating an improvement of laminar specificity over GE-BOLD fMRI. Also, the functional sensitivity of SAGE BOLD at middle layers (0.75–1.5 mm) was improved by ∼ 80% to ∼100% when compared with SE BOLD. In summary, we showed that combined GE- and SE-BOLD fMRI with the vessel-size-sensitive filter indeed yielded improved laminar specificity and sensitivity and is therefore an excellent tool for high spatial resolution ultra-high filed (UHF)-fMRI studies for resolving mesoscopic functional units.
Publisher
Academic Press
ISSN
1053-8119
Keyword (Author)
High resolution fMRIUltra-high fieldLayer specificity and sensitivityVessel-size-sensitive filterSE BOLD
Keyword
SPIN-ECHO BOLDOCULAR DOMINANCE COLUMNSGRADIENT-ECHOFUNCTIONAL MRIMAGNETIC-SUSCEPTIBILITYHIGH-RESOLUTIONVESSEL SIZEVISUAL-CORTEXBLOOD-VOLUMEHUMAN BRAIN

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.