File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

윤애정

Yoon, Aejung
Advanced Thermal Energy Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Understanding thermal stratification in cryogenic storage tanks

Author(s)
Lee, KyungwonReddy, N. KeerthiJeong, MinsubJeong, SangkwonYoon, Aejung
Issued Date
2026-05
DOI
10.1016/j.applthermaleng.2026.130579
URI
https://scholarworks.unist.ac.kr/handle/201301/91191
Fulltext
https://www.sciencedirect.com/science/article/pii/S1359431126008872?pes=vor&utm_source=clarivate&getft_integrator=clarivate
Citation
APPLIED THERMAL ENGINEERING, v.294, pp.130579
Abstract
In this study, a numerical investigation is conducted to understand thermal stratification inside cryogenic storage tanks. A numerical model is developed by coupling a 2-D liquid model with a 1-D ullage model. The model is validated against liquid nitrogen tank experiments and accurately reproduces the axial temperature distribution within +/- 3%. Using the validated model, the temporal evolution of a stratified layer is examined in tanks with various liquid heights, radii, and wall heat fluxes. The results show that the stratified-layer ratio-defined as the stratified-layer thickness normalized by the liquid height-increases more rapidly in tanks with smaller liquid heights or radii, as well as under stronger wall heating. A quantitative analysis of stratified-layer growth is performed by comparing the 2-D numerical results with 1-D theoretical predictions based on Sparrow's naturalconvection solution. The mass flow rate governing the growth of the stratified layer can be evaluated with the 1D solution, with average deviations within +/- 12%. However, because the bulk temperature varies with time, the fixed-bulk-temperature assumption in the 1-D model is not valid. Consequently, the 1-D correlation for predicting the stratified-layer ratio is valid only if an appropriate criterion is established to distinguish the warm stratified layer from the colder bulk liquid. Accordingly, a stratification criterion that enables the 1-D correlation to be extended to the 2-D domain is proposed and shown to predict the numerical results within +/- 8%. These findings advance the understanding of stratification behavior and help bridge the gap between theoretical models and numerical simulations.
Publisher
PERGAMON-ELSEVIER SCIENCE LTD
ISSN
1359-4311
Keyword (Author)
Cryogenic storage tankThermal stratificationTransient natural convection
Keyword
TRANSIENT NATURAL-CONVECTIONTEMPERATURE STRATIFICATIONPRESSURE CONTROLPRESSURIZATION

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.