File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

하준형

Ha, Junhyoung
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage E60 -
dc.citation.number 1 -
dc.citation.startPage E51 -
dc.citation.title JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY -
dc.citation.volume 161 -
dc.contributor.author Mondal, Abhijit -
dc.contributor.author Ha, Junhyoung -
dc.contributor.author Jo, Vickie Y. -
dc.contributor.author Wu, Fei-Yi -
dc.contributor.author Kaza, Aditya K. -
dc.contributor.author Dupont, Pierre E. -
dc.date.accessioned 2025-07-02T15:00:01Z -
dc.date.available 2025-07-02T15:00:01Z -
dc.date.created 2025-07-02 -
dc.date.issued 2021-01 -
dc.description.abstract Objectives: We sought to demonstrate in an animal model that helical stents made from a nickel titanium alloy called nitinol (NiTi) and designed for malacic airways could be delivered and removed without significant trauma while minimally impeding mucus clearance during the period of implantation. Methods: Stents were delivered and removed from the tracheas of healthy 20 kg swine (n = 5) using tools designed to minimize trauma. In 4-week experiments, the stents were implanted on day o, removed after 3 weeks, and swine were put to death after 4 weeks. Weekly bronchoscopies, radiographs, and mucus clearance examinations were performed in vivo. Hematoxylin and eosin staining and scanning electron microscopy imaging were used to evaluate foreign body response, tracheal tissue reaction, and damage and to measure unciliated regions. Results: In all in vivo experiments, the stent was implanted and removed atraumatically. Mucus clearance was maintained throughout the experiment period. Hematoxylin and eosin-stained slides showed that foreign body response and tracheal tissue damage were localized to the stented subsections. Tracheal tissue reaction and damage was further restricted to the epithelium and submucosal layers. Scanning electron microscopy imaging revealed that the cilia were absent only over the contact area between the trachea and the wire forming the helical stent. Conclusions: Helical nitinol stents designed to provide radial support for malacic airways were well tolerated in a porcine model, providing for mucus clearance while also enabling atraumatic removal. -
dc.identifier.bibliographicCitation JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, v.161, no.1, pp.E51 - E60 -
dc.identifier.doi 10.1016/j.jtcvs.2020.03.007 -
dc.identifier.issn 0022-5223 -
dc.identifier.scopusid 2-s2.0-85083639990 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/87280 -
dc.identifier.wosid 000608500200027 -
dc.language 영어 -
dc.publisher MOSBY-ELSEVIER -
dc.title Preclinical evaluation of a pediatric airway stent for tracheobronchomalacia -
dc.type Article -
dc.description.isOpenAccess TRUE -
dc.relation.journalWebOfScienceCategory Cardiac & Cardiovascular Systems; Respiratory System; Surgery -
dc.relation.journalResearchArea Cardiovascular System & Cardiology; Respiratory System; Surgery -
dc.type.docType Article -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordAuthor preclinical validation -
dc.subject.keywordAuthor tracheobronchomalacia -
dc.subject.keywordAuthor airway stent -
dc.subject.keywordPlus SILICONE STENTS -
dc.subject.keywordPlus CHILDREN -
dc.subject.keywordPlus INFANTS -
dc.subject.keywordPlus OBSTRUCTION -
dc.subject.keywordPlus EXPERIENCE -
dc.subject.keywordPlus MANAGEMENT -
dc.subject.keywordPlus PRESSURE -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.