File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

최경진

Choi, Kyoung Jin
Energy Conversion Materials Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 14744 -
dc.citation.number 15 -
dc.citation.startPage 14738 -
dc.citation.title ACS OMEGA -
dc.citation.volume 10 -
dc.contributor.author Kang, Jeong Eun -
dc.contributor.author Jeong, Myeong Hoon -
dc.contributor.author Choi, Kyoung Jin -
dc.date.accessioned 2025-05-07T11:30:03Z -
dc.date.available 2025-05-07T11:30:03Z -
dc.date.created 2025-04-29 -
dc.date.issued 2025-04 -
dc.description.abstract With the growing interest in wearable or stretchable electronics, research on stretchable electrodes has also been active. Generally, metal electrodes have high conductivity but very low stretchability, while organic electrodes have high stretchability but lower conductivity than metals. In this paper, metal/organic hybrid electrodes were fabricated on elastic poly(dimethylsiloxane) (PDMS) substrates to take advantage of the high conductivity of metals and the high stretchability of organic semiconductors. Additionally, by prestraining the PDMS substrate, the stretchability of the electrodes was further increased. However, the uniaxially prestrained electrodes produced compressive stresses in the direction perpendicular to the stretching direction due to Poisson's effect, resulting in many cracks. To solve this problem, biaxial prestrain was introduced to the PDMS substrate. The electrodes fabricated with uniaxial prestrain exhibited a structure with wrinkles aligned in one dimension, whereas the electrodes with biaxial prestrain displayed highly ordered, two-dimensional wrinkle patterns arranged on the electrode surface. The electrodes with biaxial prestrain maintained stable electrical performance even after 200 cycles of stretching at a strain of 50%, withstanding up to 130% strain. Furthermore, of all the poly(3,4-ethylenedioxythiophene): polystyrenesulfonate (PEDOT:PSS)-based electrodes reported so far, our electrode showed the lowest sheet resistance of 0.91 Omega/sq. The strategy of our study offers promising opportunities for integrated wearable devices. -
dc.identifier.bibliographicCitation ACS OMEGA, v.10, no.15, pp.14738 - 14744 -
dc.identifier.doi 10.1021/acsomega.4c08898 -
dc.identifier.issn 2470-1343 -
dc.identifier.scopusid 2-s2.0-105002806520 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/87004 -
dc.identifier.wosid 001462715100001 -
dc.language 영어 -
dc.publisher AMER CHEMICAL SOC -
dc.title Biaxially Prestrained Stretchable Electrodes Based on Ag/Organic Composite Film -
dc.type Article -
dc.description.isOpenAccess TRUE -
dc.relation.journalWebOfScienceCategory Chemistry, Multidisciplinary -
dc.relation.journalResearchArea Chemistry -
dc.type.docType Article -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordPlus PERFORMANCE -
dc.subject.keywordPlus CONDUCTORS -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.