File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

정후영

Jeong, Hu Young
UCRF Electron Microscopy group
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Artifact-free sample preparation of metal thin films using Xe plasma-focused ion beam milling for atomic resolution and in situ biasing analyses

Author(s)
Lee, Hee-BeomKim, Seon JeJung, Min-HyoungKim, Young-HoonKim, Su JaeGao, Hai-FengVan Leer, BrandonJeong, Se-YoungJeong, Hu YoungKim, Young-Min
Issued Date
2024-10
DOI
10.1016/j.matchar.2024.114260
URI
https://scholarworks.unist.ac.kr/handle/201301/83790
Citation
MATERIALS CHARACTERIZATION, v.216, pp.114260
Abstract
The focused ion beam (FIB) technique using Ga ion beams is generally employed for transmission electron microscopy (TEM) sampling owing to its location-specific beam controllability on materials. However, Ga ion beam bombardment-induced damage hinders reliable structural analysis. Furthermore, Ga ions implanted in the damaged surface layer substantially lower the chemical stability of the samples, such as metal thin films. Here, aiming for atomic-level interface structural analysis, we propose a useful approach for the TEM sample preparation of heteroepitaxial Ag/Cu metal films without physical damage or chemical instabilities using the Xe plasma FIB (PFIB) system. Xe plasma-assisted sampling ensured that the interface structure of the Ag/Cu metal film remained intact; in contrast, the sample prepared using the focused Ga ion beam was damaged by elemental mixing. Furthermore, the sample prepared by Xe plasma milling exhibited robust structural stability over time after exposure to air in contrast to the sample prepared by Ga-ion milling, which induced structural decomposition owing to oxidation. In addition to the static structural analysis, the Cu thin film sample prepared by Xe PFIB exclusively exhibited pristine structural properties under in situ electrical biasing experiments, thus confirming the feasibility of conducting a fundamental study of Cu electromigration without artifacts.
Publisher
ELSEVIER SCIENCE INC
ISSN
1044-5803
Keyword (Author)
Metal thin filmInterface structureTransmission electron microscopyXe plasmaFocused ion beam milling
Keyword
FIBCUMICROSCOPYINDUCED DAMAGEDIFFUSIONOXYGENAG

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.