File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

장재성

Jang, Jaesung
Sensors & Aerosols Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.number 1 -
dc.citation.startPage 135747 -
dc.citation.title JOURNAL OF HAZARDOUS MATERIALS -
dc.citation.volume 479 -
dc.contributor.author Lee, Jaegil -
dc.contributor.author Park, Chanhwi -
dc.contributor.author Jang, Jaesung -
dc.date.accessioned 2024-09-09T11:05:05Z -
dc.date.available 2024-09-09T11:05:05Z -
dc.date.created 2024-09-09 -
dc.date.issued 2024-11 -
dc.description.abstract High enrichment of airborne viruses during sampling is critical for their rapid measurement and requires a high sampling flow rate (or velocity), small collection areas, and high collection efficiency; however, high collection efficiency can rarely be achieved at high flow velocities and in small collection areas in electrostatic sampling. Herein, we present improved measurement of airborne viruses using a two-stage highly virus-enriching electrostatic particle concentrator (HEPC) with wire electrodes and high values of the-inlet-velocity-to-collection-electrode-width ratio. This sampler was evaluated using MS2 viruses and 0.05–2.0 µm diameter polystyrene latex particles at 20 liters/min. Computer simulations and experiments agreed well, showing that the wire electrodes increased collection efficiency (by up to 37 % than the without-wire-electrodes case) without high viability losses through local electric field enhancement for high-flow-velocity regions over the collection electrode and minimization of local corona discharge. The relative infectious virus concentrations of the HEPC were 41–70 times higher than those of the BioSampler. Airborne influenza A viruses at field-level concentrations (1.8 × 105 and 2.6 × 104 copies/m3) were also detected at 10-min sampling due to the high enrichment capability of HEPC. The HEPC has strong potential as a rapid airborne virus monitoring system in the field. -
dc.identifier.bibliographicCitation JOURNAL OF HAZARDOUS MATERIALS, v.479, no.1, pp.135747 -
dc.identifier.doi 10.1016/j.jhazmat.2024.135747 -
dc.identifier.issn 0304-3894 -
dc.identifier.scopusid 2-s2.0-85203050938 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/83701 -
dc.language 영어 -
dc.publisher ELSEVIER -
dc.title Improved measurement of airborne viruses using a two-stage highly virus-enriching electrostatic particle concentrator with electric-field-enhancing wire electrodes -
dc.type Article -
dc.description.isOpenAccess FALSE -
dc.type.docType Article -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordAuthor Air sampler -
dc.subject.keywordAuthor Electrostatic precipitator -
dc.subject.keywordAuthor RT-qPCR -
dc.subject.keywordAuthor Virus aerosol -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.