Reinforced concrete edge beam-column-slab connections subjected to earthquake loading

Cited 11 times inthomson ciCited 11 times inthomson ci
Title
Reinforced concrete edge beam-column-slab connections subjected to earthquake loading
Author
Shin, MyoungsuLaFave, JM
Keywords
Earthquake loading; Joint shear strengths; Strain guages; Viscous damping
Issue Date
2004-06
Publisher
ICE PUBL
Citation
MAGAZINE OF CONCRETE RESEARCH, v.56, no.5, pp.273 - 291
Abstract
Four two-thirds-scale reinforced concrete edge beam-column-slab subassemblies (two concentric and two eccentric connections) were tested under quasi-static cyclic lateral loading. Each subassembly represented a cruciform connection in an exterior moment-resisting frame with a monolithic floor slab on one side only, loaded in the longitudinal direction of the edge-beams. The tests explored the effect of eccentricity between beam and column centrelines, and the effect of floor slabs, on the structural performance of edge beam-column-slab connections subjected to earthquake loading. Performance of the specimens was evaluated in terms of overall strength and stiffness, energy dissipation, beam plastic hinge development, joint shear deformation, and joint shear strength. All specimens underwent some beam hinging at the beam/column interfaces. However, both eccentric specimens, and one concentric specimen with a heavily reinforced floor slab, eventually failed as a result of joint shear, whereas the other concentric specimen exhibited more ductile load-displacement response. The eccentric specimens (with different eccentricities and edge-beam widths) underwent similar behaviour before they started to break dawn, and they also reached similar joint shear strengths. Slab participation was evaluated using slab bar strain gauge data with respect to storey drift. Actual effective slab widths were much larger than the ones typically used in design, especially for the specimens with a column wider than the edge-beams. Finally, floor slabs imposed significant joint shear demand, but they also increased joint shear capacity by expanding effective joint width.
URI
Go to Link
DOI
10.1680/macr.56.5.273.36316
ISSN
0024-9831
Appears in Collections:
UEE_Journal Papers
Files in This Item:
There are no files associated with this item.

find_unist can give you direct access to the published full text of this article. (UNISTARs only)

Show full item record

qrcode

  • mendeley

    citeulike

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

MENU