File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

장재성

Jang, Jaesung
Sensors & Aerosols Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 3035 -
dc.citation.number 12 -
dc.citation.startPage 3028 -
dc.citation.title BIOSENSORS & BIOELECTRONICS -
dc.citation.volume 22 -
dc.contributor.author Davila, Angelica P. -
dc.contributor.author Jang, Jaesung -
dc.contributor.author Gupta, Amit K. -
dc.contributor.author Walter, Tom -
dc.contributor.author Aronson, Arthur -
dc.contributor.author Bashir, Rashid -
dc.date.accessioned 2023-12-22T09:13:56Z -
dc.date.available 2023-12-22T09:13:56Z -
dc.date.created 2014-10-16 -
dc.date.issued 2007-06 -
dc.description.abstract Towards the goal of developing a real-time monitoring device for microorganisms, we demonstrate the use of microcantilevers as resonant mass sensors for detection of Bacillus anthracis Sterne spores in air and liquid. The detection scheme was based on measuring resonant frequency decrease driven by thermally induced oscillations, as a result of the added mass of the spores with the use of a laser Doppler vibrometer (LDV). Viscous effects were investigated by comparing measurements in air and deionized (DI) water along with theoretical values. Moreover, biological experiments were performed which involved suspending spores onto the cantilevers and performing mass detection in air and water. For detection of spores in water, the cantilevers were functionalized with antibodies in order to fix the spores onto the surface. We demonstrate that as few as 50 spores on the cantilever can be detected in water using the thermal noise as excitation source. Measurement sensitivity of 9.23 Hz/fg for air and 0.1 Hz/fg for water were obtained. These measurements were compared with theoretical values and sources of improvement in cantilever sensitivity in a viscous medium were also discussed. It is expected that by driving the cantilevers and using higher order modes, detection of a single spore in liquids should be achievable. -
dc.identifier.bibliographicCitation BIOSENSORS & BIOELECTRONICS, v.22, no.12, pp.3028 - 3035 -
dc.identifier.doi 10.1016/j.bios.2007.01.012 -
dc.identifier.issn 0956-5663 -
dc.identifier.scopusid 2-s2.0-34249069463 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/7312 -
dc.identifier.url http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=34249069463 -
dc.identifier.wosid 000247555300038 -
dc.language 영어 -
dc.publisher ELSEVIER ADVANCED TECHNOLOGY -
dc.title Microresonator mass sensors for detection of Bacillus anthracis Sterne spores in air and water -
dc.type Article -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordAuthor microcantilever -
dc.subject.keywordAuthor resonant mass sensor -
dc.subject.keywordAuthor spore detection -
dc.subject.keywordAuthor viscous medium -
dc.subject.keywordPlus ATOMIC-FORCE MICROSCOPE -
dc.subject.keywordPlus MICROMECHANICAL OSCILLATORS -
dc.subject.keywordPlus PATHOGENIC BACTERIA -
dc.subject.keywordPlus FREQUENCY-RESPONSE -
dc.subject.keywordPlus CANTILEVER -
dc.subject.keywordPlus RESONATORS -
dc.subject.keywordPlus BIOSENSORS -
dc.subject.keywordPlus GROWTH -
dc.subject.keywordPlus FLUIDS -
dc.subject.keywordPlus CELLS -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.