File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

배준범

Bae, Joonbum
Bio-robotics and Control Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 11 -
dc.citation.number 4 -
dc.citation.startPage 1 -
dc.citation.title JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME -
dc.citation.volume 133 -
dc.contributor.author Bae, Joonbum -
dc.contributor.author Kong, Kyoungchul -
dc.contributor.author Byl, Nancy -
dc.contributor.author Tomizuka, Masayoshi -
dc.date.accessioned 2023-12-22T06:12:59Z -
dc.date.available 2023-12-22T06:12:59Z -
dc.date.created 2014-10-16 -
dc.date.issued 2011-04 -
dc.description.abstract Conventional gait rehabilitation treatment does not provide quantitative information on abnormal gait kinematics, and the match of the intervention strategy to the underlying clinical presentation may be limited by clinical expertise and experience. Also the effect of rehabilitation treatment may be reduced as the rehabilitation treatment is achieved only in a clinical setting. In this paper, a mobile gait monitoring system (MGMS) is proposed for the diagnosis of abnormal gait and rehabilitation. The proposed MGMS consists of Smart Shoes and a microsignal processor with a touch screen display. It monitors patients' gait by observing the ground reaction force (GRF) and the center of GRF, and analyzes the gait abnormality. Since visual feedback about patients' GRFs and normal GRF patterns are provided by the MGMS, patients can practice the rehabilitation treatment by trying to follow the normal GRF patterns without restriction of time and place. The gait abnormality proposed in this paper is defined by the deviation between the patient's GRFs and normal GRF patterns, which are constructed as GRF bands. The effectiveness of the proposed gait analysis methods with the MGMS has been verified by preliminary trials with patients suffering from gait disorders. -
dc.identifier.bibliographicCitation JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, v.133, no.4, pp.1 - 11 -
dc.identifier.doi 10.1115/1.4003525 -
dc.identifier.issn 0148-0731 -
dc.identifier.scopusid 2-s2.0-79952356001 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/7302 -
dc.identifier.url http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=79952356001 -
dc.identifier.wosid 000288706600006 -
dc.language 영어 -
dc.publisher ASME-AMER SOC MECHANICAL ENG -
dc.title A Mobile Gait Monitoring System for Abnormal Gait Diagnosis and Rehabilitation: A Pilot Study for Parkinson Disease Patients -
dc.type Article -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.