File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

김수현

Kim, Soo-Hyun
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Layer Engineered MXene Empowered Wearable Pressure Sensors for Non-Invasive Vital Human-Machine Interfacing Healthcare Monitoring

Author(s)
Mohapatra, DebanandaByun, Jeong EunAnsari, Mohd ZahidKim, HaekyoungCheon, TaehoonJang, JongmoonCho, Young-RaeLee, Jung WooKim, Soo-Hyun
Issued Date
2023-12
DOI
10.1002/admt.202301175
URI
https://scholarworks.unist.ac.kr/handle/201301/66445
Citation
ADVANCED MATERIALS TECHNOLOGIES, v.8, no.24, pp.2301175
Abstract
Pressure sensors with high flexibility and sensitivity face significant challenges in meeting the delicate balance and synergy among suitable active sensing electrode materials, substrates, and their device geometry design. In this contribution, layer-engineered delaminated Ti-MXene (DL-Ti(3)C(2)Tx) is introduced, which has relatively wider interlayer spacing through intercalated large organic molecules and accordion-like open internal microstructure than the narrower pristine Ti(3)C(2)Tx MXene (Ti-MXene), graphene/carbon nanotube's interlayer spacing suitably fulfill the high sensitivity and flexibility requirement through accessible electronic pathways under the external pressure. Notably, a milder in-situ ambient condition etching is performed to eliminate the associated safety risks for a flexible personal healthcare monitoring pressure sensor. DL-Ti(3)C(2)Tx MXene-empowered, flexible pressure sensor demonstrates a broad range of sensitivities up to a very high-pressure of 20.8 kPa at a sensitivity of 242.3 kPa(-1) with a fast response and recovery time (<300 ms). A twofold increase in pressure sensitivity performance of DL-Ti(3)C(2)Tx MXene than that of Ti-MXene, graphene can be attributed to the engineered wider interlayer distance among the delaminated DL-Ti(3)C(2)Tx MXene layers causing a facile interlayer atomic movements, contacts, and reversible compressibility. The current economical, scalable DL-Ti(3)C(2)Tx MXene flexible pressure sensor can provide future safe personal healthcare artificial intelligence with real-time tracking ability.
Publisher
WILEY
ISSN
2365-709X
Keyword (Author)
engineered Ti-MXeneflexible pressure sensorshealthcare monitoringhuman-machine interfacesinterlayer engineering

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.