A modified approach for measuring the air permeability of ultra-high performance concrete (UHPC) under vacuum conditions

Author(s)
Dahal, MandipPark, SungwooPyo, Sukhoon
Issued Date
2023-10
DOI
10.1016/j.conbuildmat.2023.132933
URI
https://scholarworks.unist.ac.kr/handle/201301/66331
Citation
CONSTRUCTION AND BUILDING MATERIALS, v.401, pp.132933
Abstract
This study proposes a novel test method of the air permeability measurement under extreme vacuum condition to examine the performance of materials for Hyperloop tubes. Tests on cement-based materials demonstrated that the developed test setup was effective in measuring air permeability in extreme vacuum conditions. The results show that ultra-high performance concrete (UHPC) has significantly lower air permeability (10–18 m2) in vacuum conditions than other cement-based materials (10–16 m2) due to its dense microstructure and reduced pore size, which were within the range of previous results (10-18-10-16 m2). The measured porosity results had a strong correlation with air permeability (R2 > 0.97), validating the suitability of the proposed method for measuring the air permeability of cement-based materials in vacuum conditions. These findings provide fundamental material properties for the design of Hyperloop tube structures.
Publisher
Elsevier BV
ISSN
0950-0618
Keyword (Author)
PorosityUHPCVacuum air permeabilityHyperloop tube
Keyword
GAS-PERMEABILITY

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.