File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

임민혁

Lim, Min Hyuk
Intelligence and Control-based BioMedicine Lab
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

A development of a graph-based ensemble machine learning model for skin sensitization hazard and potency assessment

Author(s)
Jeon, ByoungjunLim, Min HyukChoi, Tae HyunKang, Byeong-CheolKim, Sungwan
Issued Date
2022-11
DOI
10.1002/jat.4361
URI
https://scholarworks.unist.ac.kr/handle/201301/66023
Citation
JOURNAL OF APPLIED TOXICOLOGY, v.42, no.11, pp.1832 - 1842
Abstract
Many defined approaches (DAs) for skin sensitization assessment based on the adverse outcome pathway (AOP) have been developed to replace animal testing because the European Union has banned animal testing for cosmetic ingredients. Several DAs have demonstrated that machine learning models are beneficial. In this study, we have developed an ensemble prediction model utilizing the graph convolutional network (GCN) and machine learning approach to assess skin sensitization. The model integrates in silico parameters and data from alternatives to animal testing of well-defined AOP to improve DA predictivity. Multiple ensemble models were created using the probability produced by the GCN with six physicochemical properties, direct peptide reactivity assay, KeratinoSens (TM), and human cell line activation test (h-CLAT), using a multilayer perceptron approach. Models were evaluated by predicting the testing set's human hazard class and three potency classes (strong, weak, and non-sensitizer). When the GCN feature was used, 11 models out of 16 candidates showed the same or improved accuracy in the testing set. The ensemble model with the feature set of GCN, KeratinoSens (TM), and h-CLAT produced the best results with an accuracy of 88% for assessing human hazards. The best three-class potency model was created with the feature set of GCN and all three assays, resulting in 64% accuracy. These results from the ensemble approach indicate that the addition of the GCN feature could provide an improved predictivity of skin sensitization hazard and potency assessment.
Publisher
WILEY
ISSN
0260-437X
Keyword (Author)
defined approachdirect peptide reactivity assaygraph neural networkhuman cell line activation testintegrated testing strategyKeratinoSens (TM)machine learningrisk assessmentskin sensitization
Keyword
PEPTIDE REACTIVITY ASSAYLINE ACTIVATION TESTRISK-ASSESSMENTPREDICTION

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.