Dose analysis of nearby residents and workers due to the emission accident of gaseous radioactive material at the spent resin mixture treatment facility

Author(s)
Byun, JaehoonYoon, SeungbinKim, Hee Reyoung
Issued Date
2023-12
DOI
10.1016/j.net.2023.08.032
URI
https://scholarworks.unist.ac.kr/handle/201301/65412
Citation
NUCLEAR ENGINEERING AND TECHNOLOGY, v.55, no.12, pp.4543 - 4553
Abstract
The dose from a possible accident at a microwave-based spent resin mixture treatment facility that was to be installed and operated at the Wolsong nuclear power plant was analyzed to evaluate the radiological safety prior to its installation and operation. The dose to which workers and nearby residents are likely to be exposed was calculated based on the atmospheric dispersion and deposition factors using the XOQDOQ code. The highest atmospheric dispersion factors were 1.349E-05 s/m3 (workers) and 1.534E-06 s/m3 (residents). The highest doses due to emissions from the mock-up tank before operation were 1.91E-06 mSv (workers) and 1.78E-07 mSv (residents). Even after 3 h of operation, emissions from the mock-up tank had the greatest impact ranging from 4.63E-08 to 1.24E-06 mSv (workers) and 2.74E-10 to 1.16E-07 mSv (residents), respectively. The doses were 7.09E-09–4.55E-07 mSv and 4.18E-11–4.25E-08 mSv at 4–5 h of operation, and the maximum doses after operation reached 5.69E-07 mSv and 5.31E-08 mSv for the workers and residents, respectively.

Even at the exclusion area boundary (EAB), 4.76E-08–9.51E-07 mSv (annual dose:9.52E-05–1.90E-03 mSv/y) was below the dose limit of the EAB, and the safety of the facility installation inside the NPP was confirmed.
Publisher
한국원자력학회
ISSN
1738-5733
Keyword (Author)
Atmospheric dispersion factorDeposition factorDose analysisEffective doseSpent resin mixture treatment facility