Performance of the MICE diagnostic system
Cited 0 times in
Cited 0 times in
- Title
- Performance of the MICE diagnostic system
- Author
- Bogomilov, M; Chung, Moses; The MICE collaboration
- Issue Date
- 2021-08
- Publisher
- Institute of Physics
- Citation
- JOURNAL OF INSTRUMENTATION, v.16
- Abstract
- Muon beams of low emittance provide the basis for the intense, well-characterised neutrino beams of a neutrino factory and for multi-TeV lepton-antilepton collisions at a muon collider. The international Muon Ionization Cooling Experiment (MICE) has demonstrated the principle of ionization cooling, the technique by which it is proposed to reduce the phase-space volume occupied by the muon beam at such facilities. This paper documents the performance of the detectors used in MICE to measure the muon-beam parameters, and the physical properties of the liquid hydrogen energy absorber during running.