BROWSE

Related Researcher

Author's Photo

Ko, Hyunhyub
Functional Nanomaterials & Devices Lab
Research Interests
  • Functional nanomaterials, flexible electronics, electronic skins, wearable sensors

Spatiotemporal Measurement of Arterial Pulse Waves Enabled by Wearable Active-Matrix Pressure Sensor Arrays

Cited 0 times inthomson ciCited 0 times inthomson ci
Title
Spatiotemporal Measurement of Arterial Pulse Waves Enabled by Wearable Active-Matrix Pressure Sensor Arrays
Author
Baek, SanghoonLee, YoungohBaek, JinHyeokKwon, JiminKim, SeongjuLee, SeungjaeStrunk, Karl-PhilippStehlin, SebastianMelzer, ChristianPark, Sung-MinKo, HyunhyubJung, Sungjune
Issue Date
2022-01
Publisher
AMER CHEMICAL SOC
Citation
ACS NANO, v.16, no.1, pp.368 - 377
Abstract
Wearable pressure sensors have demonstrated great potential in detecting pulse pressure waves on the skin for the noninvasive and continuous diagnosis of cardiac conditions. However, difficulties lie in positioning conventional single-point sensors on an invisible arterial line, thereby preventing the detection of adequate signal amplitude for accurate pulse wave analysis. Herein, we introduce the spatiotemporal measurements of arterial pulse waves using wearable active-matrix pressure sensors to obtain optimal pulse waveforms. We fabricate thin-film transistor (TFT) arrays with high yield and uniformity using inkjet printing where array sizes can be customizable and integrate them with highly sensitive piezoresistive sheets. We maximize the pressure sensitivity (16.8 kPa(-1)) and achieve low power consumption (10(1) nW) simultaneously by strategically modulating the TFT operation voltage. The sensor array creates a spatiotemporal pulse wave map on the wrist. The map presents the positional dependence of pulse amplitudes, which allows the positioning of the arterial line to accurately extract the augmentation index, a parameter for assessing arterial stiffness. The device overcomes the positional inaccuracy of conventional single-point sensors, and therefore, it can be used for medical applications such as arterial catheter injection or the diagnosis of cardiovascular disease in daily life.
URI
https://scholarworks.unist.ac.kr/handle/201301/56568
URL
https://pubs.acs.org/doi/10.1021/acsnano.1c06695
DOI
10.1021/acsnano.1c06695
ISSN
1936-0851
Appears in Collections:
EE_Journal Papers
ECHE_Journal Papers
Files in This Item:
There are no files associated with this item.

find_unist can give you direct access to the published full text of this article. (UNISTARs only)

Show full item record

qrcode

  • mendeley

    citeulike

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

MENU