File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

RuoffRodney Scott

Ruoff, Rodney S.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Incorporation of the electrode-electrolyte interface into finite-element models of metal microelectrodes

Author(s)
Cantrell, Donald R.Inayat, SamsoonTaflove, AllenRuoff, Rodney S.Troy, John B.
Issued Date
2008-03
DOI
10.1088/1741-2560/5/1/006
URI
https://scholarworks.unist.ac.kr/handle/201301/54402
Fulltext
https://iopscience.iop.org/article/10.1088/1741-2560/5/1/006
Citation
JOURNAL OF NEURAL ENGINEERING, v.5, no.1, pp.54 - 67
Abstract
An accurate description of the electrode-electrolyte interfacial impedance is critical to the development of computational models of neural recording and stimulation that aim to improve understanding of neuro-electric interfaces and to expedite electrode design. This work examines the effect that the electrode-electrolyte interfacial impedance has upon the solutions generated from time-harmonic finite-element models of cone- and disk-shaped platinum microelectrodes submerged in physiological saline. A thin-layer approximation is utilized to incorporate a platinum-saline interfacial impedance into the finite-element models. This approximation is easy to implement and is not computationally costly. Using an iterative nonlinear solver, solutions were obtained for systems in which the electrode was driven at ac potentials with amplitudes from 10 mV to 500 mV and frequencies from 100 Hz to 100 kHz. The results of these simulations indicate that, under certain conditions, incorporation of the interface may strongly affect the solutions obtained. This effect, however, is dependent upon the amplitude of the driving potential and, to a lesser extent, its frequency. The solutions are most strongly affected at low amplitudes where the impedance of the interface is large. Here, the current density distribution that is calculated from models incorporating the interface is much more uniform than the current density distribution generated by models that neglect the interface. At higher potential amplitudes, however, the impedance of the interface decreases, and its effect on the solutions obtained is attenuated.
Publisher
IOP PUBLISHING LTD
ISSN
1741-2560
Keyword
CURRENT-DENSITY PROFILESDEEP BRAIN-STIMULATIONDISK ELECTRODEELECTROGENERATED CHEMILUMINESCENCEELECTRICAL-STIMULATIONPHYSICAL INTERPRETATIONTRANSIENT-RESPONSECOCHLEAR NUCLEUSGANGLION-CELLSROTATING DISK

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.