File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

이지민

Lee, Jimin
Radiation & Medical Intelligence Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Compton Background Elimination for in Vivo X-Ray Fluorescence Imaging of Gold Nanoparticles Using Convolutional Neural Network

Author(s)
Jung, SeongmoonLee, JiminCho, HyungjooKim, TaeyunYe, Sung-Joon
Issued Date
2020-11
DOI
10.1109/TNS.2020.3023420
URI
https://scholarworks.unist.ac.kr/handle/201301/50098
Fulltext
https://ieeexplore.ieee.org/document/9195027
Citation
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, v.67, no.11, pp.2311 - 2320
Abstract
This article reports the first application of a convolutional neural network (CNN) to in vivo X-ray fluorescence (XRF) images of gold nanoparticles (GNPs) obtained by a benchtop X-ray system to eliminate Compton-scattered photons. The XRF imaging system comprises a 2-D cadmium zinc telluride (CZT) gamma camera, a pinhole collimator, and fan-beam polychromatic X-rays. An architecture of the 2-D CNN model for Compton background elimination was optimally designed and trained with data sets obtained by the measurements of water only and GNP-embedded imaging phantoms. The XRF images generated by the trained 2-D CNN were compared with those generated by the direct subtraction method. The developed 2-D CNN was also applied to generate in vivo XRF images of gold in living mice exposed to GNPs. The in vivo XRF images generated by the two methods were then compared in terms of the difference in GNP concentrations. The results demonstrate that the 2-D CNN model was successfully applied to in vivo XRF images for detecting the concentration and location of GNPs in living mice. This also implies that in vivo XRF images can be acquired using the 2-D CNN without preinjection scanning; thus, the image acquisition time and imaging dose can be reduced by half. Furthermore, in vivo XRF images of GNPs can be acquired at any time after the injection, as the 2-D CNN eliminates the need to restrict a living object during the interscans.
Publisher
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
ISSN
0018-9499
Keyword (Author)
Two dimensional displaysEconomic indicatorsCadmium zinc telluride (CZT) gamma cameraCompton backgroundconvolutional neural network (CNN)X-ray fluorescence (XRF) imagingX-ray imagingPhotonicsImaging phantomsMiceImaging

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.