The basic approach to the performance test of the ALIP for GENIV sodium fast reactor

Author(s)
Kim, HRLee. YB
Issued Date
2016-08-19
DOI
10.1088/1755-1315/40/1/012041
URI
https://scholarworks.unist.ac.kr/handle/201301/36786
Fulltext
http://iopscience.iop.org/article/10.1088/1755-1315/40/1/012041/meta
Citation
2016 International Conference on New Energy and Future Energy System, NEFES 2016, v.40, no.1
Abstract
The annular linear induction electromagnetic pump (ALIP) with the flowrate of 900 L/min and the developed pressure of 4 bar has been designed by electric equivalent circuit analysis. It was fabricated by the consideration of materials compatible to the sodium environment of high temperature. Basic characteristic test of the ALIP was carried out in advance for its installation to the integral effect TEst Loop for safety simuLation and Assessment (STELLA) loop to confirm the sodium-thermo-hydraulic components. The test showed that the magnetic field had been linearly increased when the input current was increased, where input current and voltage had represented linear relation each other. The generated electromagnetic force was proportionate to the square of the applied current. The velocity of the aluminium pipe was proportionally increased when the input current was increased. It was verified that the basic characteristic of the ALIP showed a good accordance with the theoretical calculation.
Publisher
2016 International Conference on New Energy and Future Energy System, NEFES 2016