File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

신태주

Shin, Tae Joo
Synchrotron Radiation Research Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Small-Angle X-ray Scattering Station 4C2 BL of Pohang Accelerator Laboratory for Advance in Korean Polymer Science

Author(s)
Yoon, JinhwanKim, Kwang-WooKim, JehanHeo, KyuyoungJin, Kyeong SikJin, SangwooShin, Tae JooLee, ByeongduRho, YecheolAhn, ByungcheolRee, Moonhor
Issued Date
2008-10
DOI
10.1007/BF03218563
URI
https://scholarworks.unist.ac.kr/handle/201301/30894
Fulltext
https://link.springer.com/article/10.1007%2FBF03218563
Citation
MACROMOLECULAR RESEARCH, v.16, no.7, pp.575 - 585
Abstract
There are two beamlines (BLs), 4C1 and 4C2, at the Pohang Accelerator Laboratory that are dedicated to small angle X-ray scattering (SAXS). The 4C1 BL was constructed in early 2000 and is open to public users, including both domestic and foreign researchers. In 2003, construction of the second SAXS BL, 4C2, was complete and commissioning and user support were started. The 4C2 BL uses the same bending magnet as its light source as the 4C1 BL. The 4C1 BL uses a synthetic double multilayer monochromator, whereas the 4C2 BL uses a Si(111) double crystal monochromator for both small angle and wide angle X-ray scattering. In the 4C2 BL, the collimating mirror is positioned behind the monochromator in order to enhance the beam flux and energy resolution. A toroidal focusing mirror is positioned in front of the monochromator to increase the beam flux and eliminate higher harmonics. The 4C2 BL also contains a digital cooled charge coupled detector, which has a wide dynamic range and good sensitivity to weak scattering, thereby making it suitable for a range of SAXS and wide angle X-ray scattering experiments. The general performance of the 4C2 BL was initially tested using standard samples and further confirmed by the experience of users during three years of operation. In addition, several grazing incidence X-ray scattering measurements were carried out at the 4C2 BL.
Publisher
SPRINGER
ISSN
1598-5032
Keyword (Author)
small-angle X-ray scatteringwide-angle X-ray scatteringin-situ X-ray scatteringtransmission X-ray scatteringgazing-incidence X-ray scatteringsynchrotron radiation sourcesPohang Accelerator Laboratorybeamlinedetectorpolymers
Keyword
ORGANOSILICATE THIN-FILMSHEXAGONALLY PERFORATED LAYERTIME-RESOLVED SAXSSHORT SIDE-GROUPSCRYSTALLIZATION BEHAVIORSTRUCTURAL EVOLUTIONPOLY(ETHYLENE-TEREPHTHALATE) PETALTERNATING COPOLYIMIDESQUANTITATIVE-ANALYSISCATALYTIC-ACTIVITIES

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.