File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

배준범

Bae, Joonbum
Bio-robotics and Control Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 399 -
dc.citation.number 1 -
dc.citation.startPage 387 -
dc.citation.title JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY -
dc.citation.volume 34 -
dc.contributor.author Kim, Hyeonjun -
dc.contributor.author Park, Yeongyu -
dc.contributor.author Bae, Joonbum -
dc.date.accessioned 2023-12-21T18:11:15Z -
dc.date.available 2023-12-21T18:11:15Z -
dc.date.created 2019-11-11 -
dc.date.issued 2020-01 -
dc.description.abstract This paper presents a design and evaluation of a customized finger prosthesis that generates a natural finger motion. The design of the prosthesis followed two primary requirements: i) The size of the prosthesis should reflect that of an amputee’s finger; ii) the prosthesis should enable the natural finger motion of the amputee. To achieve these aims, two methods were employed: i) An incomplete fourbar mechanism by utilizing the remaining joint of a subject as the joint in the mechanism; ii) a fingertip trajectory analysis in polar coordinates to model the natural finger motion. In this paper, we focused on the design of the finger prosthesis so that the prototype was manufactured based on the finger information of a normal subject before applying it to the actual finger amputee. The performance of the proposed system was verified by intensive experiments for grasping and manipulation with the proposed system. -
dc.identifier.bibliographicCitation JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, v.34, no.1, pp.387 - 399 -
dc.identifier.doi 10.1007/s12206-019-1238-5 -
dc.identifier.issn 1738-494X -
dc.identifier.scopusid 2-s2.0-85077717087 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/30335 -
dc.identifier.url https://link.springer.com/article/10.1007/s12206-019-1238-5 -
dc.identifier.wosid 000511865200037 -
dc.language 영어 -
dc.publisher 대한기계학회 -
dc.title Optimized design of a body-powered finger prosthesis using fingertip trajectories based on polar coordinate analysis -
dc.type Article -
dc.description.isOpenAccess FALSE -
dc.relation.journalWebOfScienceCategory Engineering, Mechanical -
dc.relation.journalResearchArea Engineering -
dc.type.docType Article -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.description.journalRegisteredClass kci -
dc.subject.keywordAuthor Body-powered finger prosthesis -
dc.subject.keywordAuthor Four-bar mechanism -
dc.subject.keywordAuthor Under-actuation -
dc.subject.keywordAuthor Fingertip trajectory analysis -
dc.subject.keywordAuthor Modular wearable interface -
dc.subject.keywordPlus INDEX FINGER -
dc.subject.keywordPlus JOINTS -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.