File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

강주헌

Kang, Joo H.
Translational Multiscale Biofluidics Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Vertically sheathing laminar flow-based immunoassay using simultaneous diffusion-driven immune reactions

Author(s)
Kurmashev, AmanzholKwon, SeyongPark, Je-KyunKang, Joo H.
Issued Date
2019-08
DOI
10.1039/c9ra03855h
URI
https://scholarworks.unist.ac.kr/handle/201301/27255
Fulltext
https://pubs.rsc.org/en/content/articlelanding/2019/RA/C9RA03855H#!divAbstract
Citation
RSC ADVANCES, v.9, no.41, pp.23791 - 23796
Abstract
We present that enhanced simultaneous incubation of multiple antibodies (Abs) can be achieved by exploiting microfluidic laminar flows and difference in diffusivity between primary Ab (pAb) and secondary Ab (sAb). We demonstrate that injecting Ab of larger and smaller diffusivity (DAb) in an upper and lower laminar flow over the analyte-coated bottom surface, respectively, would result in enhanced signal intensity in the given reaction time. To prove this, we simultaneously infused anti-prostate specific antigen (PSA) pAb (upper laminar flow) and quantum dot (QD) labeled secondary Ab (QD-sAb) (lower laminar flow) to generate two Ab laminar flows vertically sheathing each other in the microfluidic device in which PSA was immobilized on the glass bottom surface. Because of the larger DAb of pAb than that of QD-sAb due to the heavy metal components of QD, anti-PSA pAb diffuses more rapidly toward the bottom surface where the immune reaction between PSA, pAb, and QD-sAb instantaneously occurs. We corroborated our principle by switching the position of the two Ab laminar flows (QD-sAb in upper and pAb in lower laminar flows) in the channel, which resulted in significantly lower intensity of QD signals than the previous method. Moreover, when we adjusted the interface of pAb and QD-sAb in upper and lower laminar flows, respectively, closer toward the bottom surface, the fluorescence signal was even more intensified. This is attributed to the increased flux of anti-PSA pAb more adjacent to the reaction site, which, in turn, enhances the binding efficiency of pAb to PSA on the surface.
Publisher
Royal Society of Chemistry
ISSN
2046-2069
Keyword
ELECTROCHEMICAL IMMUNOSENSORASSAYPLATFORMANTIGENBINDINGDEVICEELISA

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.