File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Rhodamine-azobenzene based single molecular probe for multiple ions sensing: Cu 2+ , Al 3+ , Cr 3+ and its imaging in human lymphocyte cells

Author(s)
Mabhai, SubhabrataDolai, MalayDey, SuryaDhara, AnamikaChoudhury, Sujata MaitiDas, BhriguramDey, SatyajitJana, Atanu
Issued Date
2019-08
DOI
10.1016/j.saa.2019.04.056
URI
https://scholarworks.unist.ac.kr/handle/201301/26703
Fulltext
https://www.sciencedirect.com/science/article/pii/S1386142519304378?via%3Dihub
Citation
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, v.219, pp.319 - 332
Abstract
A photoinduced electron transfer (PET) and chelation-enhanced fluorescence (CHEF) regulated rhodamineazobenzene chemosensor (L) was synthesized for chemoselective detection of Al3+, Cr3+, and Cu2+ by UV-Visible absorption study whereas Al3+ and Cr3+ by Iluorimetric study in EtOH-H2O solvent. L showed a clear fluorescence emission enhancement of 21 and 16 fold upon addition of Al3+ and Cr3+ due to the 1:1 host-guest complexation, respectively. This is first report on rhodamine-azobenzene based Cr3+ chemosensor. The complex formation, restricted imine isomerization, inhibition of PET (photo-induced electron transfer) process with the concomitant opening of the spirolactam ring induced a turn-on fluorescence response. The higher binding constants 6.7 x 10(3) M-1 and 3.8 x 10(3) M-1 for Al(3+ )and Cr3+, respectively and lower detection limits 1 x 10(-6)M and 2 x 10(-6) M for Al3+ and Cr3+, respectively in a buffered solution with high reversible nature describes the potential of L as an effective tool for detecting Al3+ and Cr3+ in a biological system with higher intracellular resolution. Finally, L was used to map the intracellular concentration of Al3+ and Cr3+ in human lymphocyte cells (HLCs) at physiological pH very effectively. Altogether, our findings will pave the way for designing new chemosensors for multiple analytes and those chemosensors will be effective for cell imaging study.
Publisher
Elsevier B.V.
ISSN
1386-1425
Keyword (Author)
AzobenzeneCHEFChemosensorPETRhodamine
Keyword
ON FLUORESCENCE CHEMOSENSORDENSITY-FUNCTIONAL THEORYSPECTROSCOPIC PROPERTIESSELECTIVE RECOGNITIONEXCITATION-ENERGIESCRYSTAL-STRUCTURESENSORHG2+APPROXIMATIONSTATES

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.