File Download

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

조형준

Cho, Hyungjoon
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Cerebral blood perfusion deficits using dynamic susceptibility contrast MRI with gadolinium chelates in rats with post-ischemic reperfusion without significant dynamic contrast-enhanced MRI-derived vessel permeabilities: A cautionary note

Author(s)
Jin, SeokhaKang, MungSooCho, Hyungjoon
Issued Date
2018-07
DOI
10.1371/journal.pone.0201076
URI
https://scholarworks.unist.ac.kr/handle/201301/24420
Fulltext
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0201076
Citation
PLOS ONE, v.13, no.7, pp.e0201076
Abstract
In this study, we quantified perfusion deficits using dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) with an extravasating contrast agent (CA). We also investigated the efficacy of leakage compensation from CA pre-load in brains from post-ischemic rat models without significant dynamic contrast-enhanced MRI (DCE-MRI)-derived vessel wall permeability. DSC measurements were obtained using fast (0.3 s) echo-planar imaging in both normal rats and rats with transient middle carotid artery occlusion (MCAO) (1-h MCAO, 24-h reperfusion) after successive administrations of gadoterate meglumine (Dotarem) and intravascular superparamagnetic iron oxide nanoparticles (SPION). The relative cerebral blood volume (CBV) and cerebral blood flow (CBF) values acquired using Dotarem were significantly underestimated (~20%) when compared to those acquired using SPION in ipsilesional post-ischemic brain regions. A slight overestimation of relative mean transit time was observed. Areas with underestimated CBV and CBF values from the corresponding error maps encompassed the area of infarcted tissue (apparent diffusion coefficient < 500 μm2/s) and mostly coincided with the area wherein conspicuous longitudinal relaxation time differences were observed pre- vs. post-injection of Dotarem. The DSC measurements with significant pre-load (0.3 mmol·kg-1) of Dotarem displayed minimal perfusion deficits when compared to those determined using the reference intravascular SPION.
Publisher
PUBLIC LIBRARY SCIENCE
ISSN
1932-6203
Keyword
BRAIN-BARRIER BREAKDOWNULTRASHORT ECHO TIMEVASCULAR-PERMEABILITYAGENT EXTRAVASATIONDCE-MRIVOLUMEPARAMETERSISCHEMIASTROKESIZE

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.