File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

신태주

Shin, Tae Joo
Synchrotron Radiation Research Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Dark current reduction strategies using edge-on aligned donor polymers for high detectivity and responsivity organic photodetectors

Author(s)
Eom, Seung HunNam, So YounDo, Hee JinLee, JaeminJeon, SanghoShin, Tae JooJung, In HwanYoon, Sung CheolLee, Changjin
Issued Date
2017-06
DOI
10.1039/c7py00497d
URI
https://scholarworks.unist.ac.kr/handle/201301/22396
Fulltext
http://pubs.rsc.org/en/Content/ArticleLanding/2017/PY/C7PY00497D#!divAbstract
Citation
POLYMER CHEMISTRY, v.8, no.23, pp.3612 - 3621
Abstract
We synthesized the conjugated polymers PT2OBT, PVT2OBT, and PFBT2OBT for use in organic photo-detecting devices. An octyloxy benzothiadiazole (OBT) moiety was used as a weak electron-accepting building block in the polymer system to cause the dominant absorption in the green-light region via weakening the intramolecular charge transfer (ICT) interactions between adjacent electron-donating moieties. In particular, indirect X-ray detection using a scintillator requires a low leakage current; thus, we focused on designing a molecular structure that can enhance the detectivity. The difluorobenzene-incorporated PFBT2OBT polymer showed a strong edge-on orientation both in the pristine film and in the blend film; however, PT2OBT and PVT2OBT have no preferred molecular orientation in the blend film. In the edge-on structure, the alkyl side chains of PFBT2OBT align on the surface of the electrode, forming an insulating layer, which decreases the tunneling leakage current, whereas in the latter cases, the interface between the semiconducting polymer backbone and PC70BM can come into contact with the electrode, forming a pathway for the leakage current. Consequently, the PFBT2OBT: PC70BM devices showed promising detectivities of over 10(13) Jones over a wide range of reverse biases of up to -2 V, resulting from their low dark current density of less than 2.3 x 10(-9) A cm(-2).
Publisher
ROYAL SOC CHEMISTRY
ISSN
1759-9954
Keyword
THIN-FILM TRANSISTORSSOLAR-CELLSPRESSURE SENSORSTEMPERATURE SENSORSCONJUGATED POLYMERSELECTRON-TRANSPORTHIGH-PERFORMANCE300 NMPHOTODIODESCOPOLYMERS

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.