Human Error Mode Identification for NPP Main Control Room Operations Using Soft Controls

Author(s)
Lee, Seung JunKim, JaewhanJang, Seung-Cheol
Issued Date
2011-06
DOI
10.1080/18811248.2011.9711776
URI
https://scholarworks.unist.ac.kr/handle/201301/19941
Fulltext
http://www.tandfonline.com/doi/abs/10.1080/18811248.2011.9711776
Citation
JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, v.48, no.6, pp.902 - 910
Abstract
The operation environment of main control rooms (MCRs) in modern nuclear power plants (NPPs) has considerably changed over the years. Advanced MCRs, which have been designed by adapting digital and computer technologies, have simpler interfaces using large display panels, computerized displays, soft controls, computerized procedure systems, and so on. The actions for the NPP operations are performed using soft controls in advanced MCRs. Soft controls have different features from conventional controls. Operators need to navigate the screens to find indicators and controls and manipulate controls using a mouse, touch screens, and so on. Due to these different interfaces, different human errors should be considered in the human reliability analysis (HRA) for advanced MCRs. In this work, human errors that could occur during operation executions using soft controls were analyzed. This work classified the human errors in soft controls into six types, and the reasons that affect the occurrence of the human errors were also analyzed
Publisher
TAYLOR & FRANCIS LTD
ISSN
0022-3131

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.