File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

강상훈

Kang, Sang Hoon
Robotics and Rehabilitation Engineering Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 112 -
dc.citation.number 1 -
dc.citation.startPage 97 -
dc.citation.title JOURNAL OF NEUROSCIENCE METHODS -
dc.citation.volume 189 -
dc.contributor.author Chang, Pyung Hun -
dc.contributor.author Kang, Sang Hoon -
dc.date.accessioned 2023-12-22T07:09:04Z -
dc.date.available 2023-12-22T07:09:04Z -
dc.date.created 2015-08-06 -
dc.date.issued 2010-05 -
dc.description.abstract The basic assumption of stochastic human arm impedance estimation methods is that the human arm and robot behave linearly for small perturbations. In the present work, we have identified the degree of influence of nonlinear friction in robot joints to the stochastic human arm impedance estimation. Internal model based impedance control (IMBIC) is then proposed as a means to make the estimation accurate by compensating for the nonlinear friction. From simulations with a nonlinear Lugre friction model, it is observed that the reliability and accuracy of the estimation are severely degraded with nonlinear friction: below 2. Hz, multiple and partial coherence functions are far less than unity; estimated magnitudes and phases are severely deviated from that of a real human arm throughout the frequency range of interest; and the accuracy is not enhanced with an increase of magnitude of the force perturbations. In contrast, the combined use of stochastic estimation and IMBIC provides with accurate estimation results even with large friction: the multiple coherence functions are larger than 0.9 throughout the frequency range of interest and the estimated magnitudes and phases are well matched with that of a real human arm. Furthermore, the performance of suggested method is independent of human arm and robot posture, and human arm impedance. Therefore, the IMBIC will be useful in measuring human arm impedance with conventional robot, as well as in designing a spatial impedance measuring robot, which requires gearing. © 2010 Elsevier B.V. -
dc.identifier.bibliographicCitation JOURNAL OF NEUROSCIENCE METHODS, v.189, no.1, pp.97 - 112 -
dc.identifier.doi 10.1016/j.jneumeth.2010.02.021 -
dc.identifier.issn 0165-0270 -
dc.identifier.scopusid 2-s2.0-77952551792 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/13412 -
dc.identifier.url http://www.sciencedirect.com/science/article/pii/S0165027010001159 -
dc.identifier.wosid 000278290900015 -
dc.language 영어 -
dc.publisher ELSEVIER SCIENCE BV -
dc.title Stochastic estimation of human arm impedance under nonlinear friction in robot joints: A model study -
dc.type Article -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.