Efficient removals of tris(2-chloroethyl) phosphate (TCEP) and perchlorate using NF membrane filtrations

Cited 12 times inthomson ciCited 14 times inthomson ci
Title
Efficient removals of tris(2-chloroethyl) phosphate (TCEP) and perchlorate using NF membrane filtrations
Author
Lee, SungyunQuyet, N.Lee, EunkyungKim, SuhanLee, SangyoupJung, Young D.Choi, Seok HoCho, Jaeweon
Keywords
Desalination; Micropollutant; NF; Perchlorate; TCEP
Issue Date
2008-03
Publisher
ELSEVIER SCIENCE BV
Citation
DESALINATION, v.221, no.1-3, pp.234 - 237
Abstract
Perchlorate and tris(2-chloroethyl) phosphate (TCEP), which have been widely detected micropollutants in rivers and wastewater effluents, were investigated in terms of removals by nanofiltration (NF) membranes under different membrane feed water conditions. For this study, NF membranes with different characteristics, including molecular weight cutoff (MWCO), relative hydrophobicity, and roughness, were used. To demonstrate the effect of electrostatic repulsion between the membrane surface and investigated compounds, the conductivity of membrane feed solutions were altered using sodium chloride; the effects of natural organic matters on removal efficiencies of tested compounds were also demonstrated using synthetic model solutions and the Youngsan River water. Filtration tests with seawater were conducted to investigate applicability of NF membranes for desalination. A relatively loose NF membrane with lower hydrophobicity and lower roughness exhibited lower removal efficiencies for both perchlorate and TCEP than the other tight NF membranes with lower MWCO. When comparing removal efficiencies of perchlorate and TCEP for the loose NF membrane, removals of uncharged TCEP were less affected by differences in solution chemistry variations than those of perchlorate. The tight NF membranes exhibited higher removal efficiencies for both perchlorate and TCEP than the loose NF membrane, as expected, under tested conditions, including seawater
URI
Go to Link
DOI
10.1016/j.desal.2007.02.054
ISSN
0011-9164
Appears in Collections:
UEE_Journal Papers
Files in This Item:
1-s2.0-S0011916407006972-main.pdf Download

find_unist can give you direct access to the published full text of this article. (UNISTARs only)

Show full item record

qrcode

  • mendeley

    citeulike

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

MENU