Design Methodology of Bidirectional CLLC Resonant Converter for High-Frequency Isolation of DC Distribution Systems

Cited 17 times inthomson ciCited 26 times inthomson ci
Title
Design Methodology of Bidirectional CLLC Resonant Converter for High-Frequency Isolation of DC Distribution Systems
Author
Jung, Jee-HoonKim, Ho-SungRyu, Myung-HyoBaek, Ju-Won
Keywords
Bidirectional converter; CLLC resonance; dc distribution; High-frequency isolation; Soft switching
Issue Date
2013-04
Publisher
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
Citation
IEEE TRANSACTIONS ON POWER ELECTRONICS, v.28, no.4, pp.1741 - 1755
Abstract
A bidirectional full-bridge CLLC resonant converter using a new symmetric LLC-type resonant network is proposed for a low-voltage direct current power distribution system. This converter can operate under high power conversion efficiency because the symmetric LLC resonant network has zero-voltage switching capability for primary power switches and soft commutation capability for output rectifiers. In addition, the proposed topology does not require any snubber circuits to reduce the voltage stress of the switching devices because the switch voltage of the primary and secondary power stage is confined by the input and output voltage, respectively. In addition, the power conversion efficiency of any directions is exactly same as each other.Using digital control schemes, a 5-kW prototype converter designed for a high-frequency galvanic isolation of 380-V dc buses was developed with a commercial digital signal processor. Intelligent digital control algorithms are also proposed to regulate output voltage and to control bidirectional power conversions. Using the prototype converter, experimental results were obtained to verify the performance of the proposed topology and control algorithms. The converter could softly change the power flow directions and its maximum power conversion efficiency was 97.8% during the bidirectional operation.
URI
Go to Link
DOI
10.1109/TPEL.2012.2213346
ISSN
0885-8993
Appears in Collections:
EE_Journal Papers
Files in This Item:
2-s2.0-84882972757.pdf Download

find_unist can give you direct access to the published full text of this article. (UNISTARs only)

Show full item record

qrcode

  • mendeley

    citeulike

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

MENU