The effective coefficient of secondary electron emission in plasma display panel

Author(s)
Hur, Min SupLee, JKKim, HCKang, BK
Issued Date
2001-10
URI
https://scholarworks.unist.ac.kr/handle/201301/8801
Fulltext
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=0035485491
Citation
IEEE TRANSACTIONS ON PLASMA SCIENCE, v.29, no.5, pp.861 - 863
Abstract
The effective secondary electron emission coefficient (SEEC) in a plasma display panel (PDP) is estimated by comparing the Paschen breakdown curves from simulations with the experiment. It is found that the effective SEEC in PDP is dependent on the ratio of electric field to pressure. The estimated values are 0.59 similar to0.79 for the pure Ne and 0.1 similar to0.13 for the Ne-Xe (96/4) mixture, respectively.
Publisher
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC