File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

신명수

Shin, Myoungsu
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.startPage 108962 -
dc.citation.title STRUCTURES -
dc.citation.volume 77 -
dc.contributor.author Cuong, Tran-Hung -
dc.contributor.author Pham, Khoa Vo Anh -
dc.contributor.author Jo, Hyerim -
dc.contributor.author Shin, Myoungsu -
dc.contributor.author Shin, Jiuk -
dc.contributor.author Lee, Kihak -
dc.date.accessioned 2025-06-27T13:00:04Z -
dc.date.available 2025-06-27T13:00:04Z -
dc.date.created 2025-06-12 -
dc.date.issued 2025-07 -
dc.description.abstract The performance of precast components is greatly influenced by the behavior of their joints. This study investigated the use of steel box connectors to connect precast column-beam components, focusing on structural seismic performance through experimental testing and numerical simulation. Full-scale specimens with and without steel box connectors were tested under cyclic loading. The results showed that steel box connectors significantly improved the joint behavior, improving the structural strength by 6.18% and ductility by 1.26 times, while also providing flexibility, ease of installation and maintenance. The specimens with connectors showed slower failure progression and improved earthquake survivability compared to specimens without connectors, which failed rapidly with diagonal cracks. The connectors themselves remained undamaged throughout the testing. In particular, the 30 mm thick steel box provides the best balance between strength and ductility, making it the optimal solution for precast column-beam joints. -
dc.identifier.bibliographicCitation STRUCTURES, v.77, pp.108962 -
dc.identifier.doi 10.1016/j.istruc.2025.108962 -
dc.identifier.issn 2352-0124 -
dc.identifier.scopusid 2-s2.0-105004906516 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/87231 -
dc.identifier.wosid 001494700100001 -
dc.language 영어 -
dc.publisher ELSEVIER SCIENCE INC -
dc.title Evaluation of the seismic behavior-based FE analysis of steel box connectors in precast column-beam joints -
dc.type Article -
dc.description.isOpenAccess FALSE -
dc.relation.journalWebOfScienceCategory Engineering, Civil -
dc.relation.journalResearchArea Engineering -
dc.type.docType Article -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordAuthor Precast column-beam connection -
dc.subject.keywordAuthor Precast structure -
dc.subject.keywordAuthor Steel box connector -
dc.subject.keywordPlus PERFORMANCE -
dc.subject.keywordPlus DAMAGE -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.