File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

유재준

Yoo, Jaejun
Lab. of Advanced Imaging Technology
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.number 1 -
dc.citation.startPage 5924 -
dc.citation.title SCIENTIFIC REPORTS -
dc.citation.volume 15 -
dc.contributor.author Kim, Pum Jun -
dc.contributor.author Kim, Dongyoung -
dc.contributor.author Lee, Joonwon -
dc.contributor.author Kim, Hyung Chan -
dc.contributor.author Seo, Jung Hwa -
dc.contributor.author Lee, Suk Yoon -
dc.contributor.author Kwon, Doo Hyuk -
dc.contributor.author Park, Hyungjong -
dc.contributor.author Yoo, Jaejun -
dc.contributor.author Park, Seongho -
dc.date.accessioned 2025-04-25T15:09:47Z -
dc.date.available 2025-04-25T15:09:47Z -
dc.date.created 2025-03-05 -
dc.date.issued 2025-02 -
dc.description.abstract The presence of a diffusion-weighted imaging (DWI)-fluid-attenuated inversion recovery (FLAIR) mismatch holds potential value in identifying candidates for recanalization treatment. However, the visual assessment of DWI-FLAIR mismatch is subject to limitations due to variability among raters, which affects accuracy and consistency. To overcome these challenges, we aimed to develop and validate a deep learning-based classifier to categorize the mismatch. We screened consecutive acute ischemic stroke patients who underwent DWI and FLAIR imaging from a four stroke centers. Two centers were used for model development and internal testing (derivation cohort), while two independent centers served as external validation cohorts. We developed Convolutional Neural Network-based classifiers for two binary classifications: DWI-FLAIR match versus non-match (Label Set I) and match versus mismatch (Label Set II). A total of 2369 patients from the derivation set and 679 patients from two external validation sets (350 and 329 patients) were included in the analysis. For Label Set I, the internal test set AUC was 0.862 (95% CI 0.841-0.884, with external validation AUCs of 0.829 (0.785-0.873) and 0.835 (0.790-0.879). Label Set II showed higher performance with internal test AUC of 0.934 (0.911-0.957) and external validation AUCs of 0.883 (0.829-0.938) and 0.913 (0.876-0.951). A deep learning-based classifier for the DWI-FLAIR mismatch can be used to diminish subjectivity and support targeted decision-making in the treatment of acute stroke patients. -
dc.identifier.bibliographicCitation SCIENTIFIC REPORTS, v.15, no.1, pp.5924 -
dc.identifier.doi 10.1038/s41598-025-90214-w -
dc.identifier.issn 2045-2322 -
dc.identifier.scopusid 2-s2.0-85219114272 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/86744 -
dc.identifier.wosid 001425502000029 -
dc.language 영어 -
dc.publisher NATURE PORTFOLIO -
dc.title Deep learning-based classification of diffusion-weighted imaging-fluid-attenuated inversion recovery mismatch -
dc.type Article -
dc.description.isOpenAccess TRUE -
dc.relation.journalWebOfScienceCategory Multidisciplinary Sciences -
dc.relation.journalResearchArea Science & Technology - Other Topics -
dc.type.docType Article -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordAuthor Ischemic stroke -
dc.subject.keywordAuthor Cerebral infarction -
dc.subject.keywordAuthor Deep learning -
dc.subject.keywordAuthor Machine learning -
dc.subject.keywordAuthor Diffusion-FLAIR mismatch -
dc.subject.keywordPlus THROMBOLYSIS -
dc.subject.keywordPlus FLAIR -
dc.subject.keywordPlus DWI -
dc.subject.keywordPlus ACUTE ISCHEMIC-STROKE -
dc.subject.keywordPlus SIGNAL INTENSITY -
dc.subject.keywordPlus SYMPTOM ONSET -
dc.subject.keywordPlus TIME -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.