File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

이종훈

Lee, Zonghoon
Atomic-Scale Electron Microscopy Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 2249 -
dc.citation.number 8 -
dc.citation.startPage 2241 -
dc.citation.title MICROSCOPY RESEARCH AND TECHNIQUE -
dc.citation.volume 88 -
dc.contributor.author Calkovsky, Martin -
dc.contributor.author Chung, Handolsam -
dc.contributor.author Choe, Myeonggi -
dc.contributor.author Lee, Yeongdong -
dc.contributor.author Lee, Zonghoon -
dc.date.accessioned 2025-04-25T15:07:44Z -
dc.date.available 2025-04-25T15:07:44Z -
dc.date.created 2025-04-02 -
dc.date.issued 2025-08 -
dc.description.abstract Commercially available windowed gas cells for in situ scanning transmission electron microscopy (STEM) opened vast possibilities to study gas-solid interactions with high-spatial resolution. Modern gas cell designs comprise efforts to maintain the high-spatial resolution of the primary electron beam by reducing SiN window and gas thickness. Despite these efforts, the primary electron beam still interacts with the pre-sample gas atmosphere and SiN window, which leads to the deterioration of the initial spatial resolution of the primary electron beam and degrades the STEM image quality. In the presented work, we aim to understand the STEM resolution deterioration mechanisms by utilizing Monte Carlo simulations to reveal information on electron scattering in the SiN window and pre-sample gas atmosphere. Additionally, we use the derived understanding of the STEM resolution deterioration mechanisms to propose measures to avoid STEM resolution deterioration in in situ gas cell STEM experiments. Monte Carlo simulations reveal that the STEM resolution limiting factor in the gas cell is an insufficient signal-to-noise ratio (SNR). By increasing the SNR in the acquired STEM images, the resolution in the STEM images is improved. The proposed approach is demonstrated on a WS2 specimen imaged under 0 and 1000 mbar Ar gas pressure. -
dc.identifier.bibliographicCitation MICROSCOPY RESEARCH AND TECHNIQUE, v.88, no.8, pp.2241 - 2249 -
dc.identifier.doi 10.1002/jemt.24856 -
dc.identifier.issn 1059-910X -
dc.identifier.scopusid 2-s2.0-105000823301 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/86687 -
dc.identifier.url https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/10.1002/jemt.24856 -
dc.identifier.wosid 001447402100001 -
dc.language 영어 -
dc.publisher WILEY -
dc.title Resolution Deterioration of Scanning Transmission Electron Microscope in a Windowed Gas Cell -
dc.type Article -
dc.description.isOpenAccess TRUE -
dc.relation.journalWebOfScienceCategory Anatomy & Morphology; Biology; Microscopy -
dc.relation.journalResearchArea Anatomy & Morphology; Life Sciences & Biomedicine - Other Topics; Microscopy -
dc.type.docType Article; Early Access -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordAuthor electron scattering -
dc.subject.keywordAuthor Monte Carlo simulations -
dc.subject.keywordAuthor STEM resolution -
dc.subject.keywordAuthor 2D materials -
dc.subject.keywordAuthor gas cell -
dc.subject.keywordPlus SPATIAL-RESOLUTION -
dc.subject.keywordPlus SINGLE ATOMS -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.