File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

조형준

Cho, Hyungjoon
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 140 -
dc.citation.number 1 -
dc.citation.startPage 127 -
dc.citation.title IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL -
dc.citation.volume 72 -
dc.contributor.author Lee, Moon Hwan -
dc.contributor.author Lee, Kyungsu -
dc.contributor.author Yoo, Youngseung -
dc.contributor.author Cho, Hyungjoon -
dc.contributor.author Chung, Euiheon -
dc.contributor.author Hwang, Jae Youn -
dc.date.accessioned 2024-12-04T10:05:06Z -
dc.date.available 2024-12-04T10:05:06Z -
dc.date.created 2024-12-03 -
dc.date.issued 2025-01 -
dc.description.abstract Ultrasound neuromodulation (UNM) has gained significant interest in brain science due to its non-invasive nature, precision, and deep brain stimulation capabilities. However, the skull poses challenges along the acoustic path, leading to beam distortion and necessitating effective acoustic aberration correction. Acoustic holograms used with single-element ultrasound transducers offer a promising solution by enabling both aberration correction and multi-focal stimulation. A major limitation, however, is that hologram lenses designed for specific skulls may not perform well on other skulls, requiring multiple custom lenses for scaled studies. To address this, we introduce the Skull-Universal Acoustic Hologram (SUAH), which enables efficient transcranial UNM across various skull types. Our hologram generation framework integrates a physics-based acoustic hologram, differentiable acoustic simulation in heterogeneous media, and a gradient accumulation technique. SUAH, trained on a range of rodent skull shapes, demonstrated remarkable generalizability and robustness, even outperforming the Skull-Specific Acoustic Hologram (SSAH). Through comprehensive analyses, we showed that SUAH performs exceptionally well—even when trained on smaller datasets—significantly outperforming training based on individual skulls. In conclusion, SUAH shows promise as a scalable, versatile, and accurate tool for ultrasound neuromodulation, representing a significant advancement over conventional single-skull hologram lenses. Its ability to adapt to different skull types without the need for multiple custom lenses has the potential to greatly facilitate research in ultrasound neuromodulation. -
dc.identifier.bibliographicCitation IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, v.72, no.1, pp.127 - 140 -
dc.identifier.doi 10.1109/TUFFC.2024.3506913 -
dc.identifier.issn 0885-3010 -
dc.identifier.scopusid 2-s2.0-85211214430 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/84672 -
dc.identifier.wosid 001410884500008 -
dc.language 영어 -
dc.publisher IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC -
dc.title Machine Learning-Enhanced Skull-Universal Acoustic Hologram for Efficient Transcranial Ultrasound Neuromodulation Across Varied Rodent Skulls -
dc.type Article -
dc.description.isOpenAccess FALSE -
dc.relation.journalWebOfScienceCategory Acoustics;Engineering -
dc.relation.journalResearchArea Acoustics;Engineering -
dc.type.docType Article -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordAuthor Acoustics -
dc.subject.keywordAuthor Ultrasonic imaging -
dc.subject.keywordPlus FOCUSED ULTRASOUND -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.