File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

이강수

Lee, Kang Soo
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 927 -
dc.citation.number 2 -
dc.citation.startPage 922 -
dc.citation.title RSC ADVANCES -
dc.citation.volume 5 -
dc.contributor.author Choi, Jeongan -
dc.contributor.author Lee, Kang Soo -
dc.contributor.author Jung, Jin Ho -
dc.contributor.author Sung, Hyung Jin -
dc.contributor.author Kim, Sang Soo -
dc.date.accessioned 2024-07-22T17:05:12Z -
dc.date.available 2024-07-22T17:05:12Z -
dc.date.created 2024-07-22 -
dc.date.issued 2015-11 -
dc.description.abstract This paper describes the realization of highly sensitive surface-enhanced Raman spectroscopy (SERS) via an integrated three-dimensional liquid-core/liquid-cladding waveguide. The cladding flow enclosed the core flow in both the horizontal and vertical directions within a single-layered microfluidic channel, and the laser beam was guided through the core stream. Deionized water was used to suspend SERS-active silver nanocolloids to form the core fluid, and 2,2,2-trifluoroethanol was used as the cladding fluid. Dipicolinic acid, commonly used as a biomarker for the detection of Bacillus anthracis, was employed as the target analyte. The sensitivity of the SERS signal was enhanced through this design because the signals backscattered from the analytes accumulated along the core stream and increased the SERS detection volume. The SERS data was evaluated in terms of the analyte concentration in the core fluid, the irradiated laser power, and the cross-sectional area of the core stream. The present data were compared with a conventional SERS detection approach in order to quantify the enhancement factor. The detection limit of concentration, 50 nM at an acquisition time of 6 s, was a factor of 35 smaller than that of conventional methods. -
dc.identifier.bibliographicCitation RSC ADVANCES, v.5, no.2, pp.922 - 927 -
dc.identifier.doi 10.1039/c4ra11027g -
dc.identifier.issn 2046-2069 -
dc.identifier.scopusid 2-s2.0-84916623134 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/83244 -
dc.identifier.wosid 000346079900009 -
dc.language 영어 -
dc.publisher ROYAL SOC CHEMISTRY -
dc.title Integrated real-time optofluidic SERS via a liquid-core/liquid-cladding waveguide -
dc.type Article -
dc.description.isOpenAccess FALSE -
dc.relation.journalWebOfScienceCategory Chemistry, Multidisciplinary -
dc.relation.journalResearchArea Chemistry -
dc.type.docType Article -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordPlus BACILLUS-SUBTILIS ENDOSPORE -
dc.subject.keywordPlus SPECTROSCOPY -
dc.subject.keywordPlus INTENSITY -
dc.subject.keywordPlus MICROSCOPY -
dc.subject.keywordPlus DEVICE -
dc.subject.keywordPlus SENSOR -
dc.subject.keywordPlus LIGHT -
dc.subject.keywordPlus FIBER -
dc.subject.keywordPlus ENHANCED RAMAN-SCATTERING -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.