File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

원종묵

Won, Jongmuk
Sustainable Smart Geotechnical Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.number 4 -
dc.citation.title SUSTAINABILITY -
dc.citation.volume 15 -
dc.contributor.author Lee, Seokjae -
dc.contributor.author Park, Sangwoo -
dc.contributor.author Han, Taek Hee -
dc.contributor.author Won, Jongmuk -
dc.contributor.author Choi, Hangseok -
dc.date.accessioned 2024-07-12T11:05:12Z -
dc.date.available 2024-07-12T11:05:12Z -
dc.date.created 2024-07-11 -
dc.date.issued 2023-02 -
dc.description.abstract A floor slab of buildings can be used as a ground heat exchanger by equipping heat exchange pipes with a horizontal layout, namely energy slabs. The thermal performance of conventional energy slabs is relatively low due to the interference with the ambient air temperature. This fatal drawback can be overcome by installing energy slabs in an underground parking lot, where the influence of ambient air is not significant. This study experimentally investigated the applicability of two types of energy slabs (floor type and wall type), which were constructed on the basement slab in an underground parking lot. In particular, an aerogel-type thermal insulation layer was fabricated in each energy slab to isolate it from the ambient air along with enhancing the structural stability against automobiles. In the thermal performance tests, the constructed energy slabs showed a thermal performance 265% higher than the conventional energy slabs. Moreover, the aerogel-type thermal insulation layer effectively prevented surface condensation. However, the thermal stress of 2350 kPa was induced by the cooling operation in the energy slabs, which means the energy slab should possess sufficient tensile strength to secure the structural integrity of the parking lot basement. -
dc.identifier.bibliographicCitation SUSTAINABILITY, v.15, no.4 -
dc.identifier.doi 10.3390/su15042973 -
dc.identifier.issn 2071-1050 -
dc.identifier.scopusid 2-s2.0-85149214508 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/83108 -
dc.identifier.wosid 000941481400001 -
dc.language 영어 -
dc.publisher MDPI -
dc.title Applicability Evaluation of Energy Slabs Installed in an Underground Parking Lot -
dc.type Article -
dc.description.isOpenAccess TRUE -
dc.relation.journalWebOfScienceCategory Green & Sustainable Science & Technology; Environmental Sciences; Environmental Studies -
dc.relation.journalResearchArea Science & Technology - Other Topics; Environmental Sciences & Ecology -
dc.type.docType Article -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass ssci -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordAuthor energy slab -
dc.subject.keywordAuthor ground heat exchanger -
dc.subject.keywordAuthor thermal insulation -
dc.subject.keywordAuthor thermal performance test -
dc.subject.keywordAuthor underground parking lot -
dc.subject.keywordPlus SOURCE HEAT-PUMP -
dc.subject.keywordPlus MECHANICAL-BEHAVIOR -
dc.subject.keywordPlus EXERGY ANALYSIS -
dc.subject.keywordPlus PERFORMANCE -
dc.subject.keywordPlus EXCHANGERS -
dc.subject.keywordPlus SYSTEM -
dc.subject.keywordPlus STRENGTH -
dc.subject.keywordPlus TUNNEL -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.