A Terminal Ground Filter between Cable and Chassis for Reduction of Conducted Emissions at a Home Appliance

Author(s)
Jeong, SangyeongKim, JingookBaek, YoungjinLee, WonwooPark, Gwigeun
Issued Date
2018-07-30
DOI
10.1109/EMCSI.2018.8495422
URI
https://scholarworks.unist.ac.kr/handle/201301/81106
Fulltext
https://ieeexplore.ieee.org/document/8495422
Citation
2018 IEEE Symposium on Electromagnetic Compatibility, Signal Integrity and Power Integrity, EMC, SI and PI 2018
Abstract
A CM noise reduction method by adding a terminal ground filter between the cable ground and chassis is proposed. The noise reduction performance of the terminal ground filter is estimated with a simplified circuit model. The proposed filter is implemented in a small PCB, and applied to a 3.3kW power system of an air conditioner. The reduction of the CM CE noises by applying the terminal ground filter is experimentally validated.