File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

전세영

Chun, Se Young
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 305 -
dc.citation.number 2 -
dc.citation.startPage 295 -
dc.citation.title IEEE TRANSACTIONS ON MEDICAL IMAGING -
dc.citation.volume 32 -
dc.contributor.author Chun, Se Young -
dc.contributor.author Fessler, Jeffrey A. -
dc.contributor.author Dewaraja, Yuni K. -
dc.date.accessioned 2023-12-22T04:12:26Z -
dc.date.available 2023-12-22T04:12:26Z -
dc.date.created 2014-10-29 -
dc.date.issued 2013-02 -
dc.description.abstract Compensating for the collimator-detector response (CDR) in SPECT is important for accurate quantification. The CDR consists of both a geometric response and a septal penetration and collimator scatter response. The geometric response can be modeled analytically and is often used for modeling the whole CDR if the geometric response dominates. However, for radionuclides that emit medium or high-energy photons such as I-131, the septal penetration and collimator scatter response is significant and its modeling in the CDR correction is important for accurate quantification. There are two main methods for modeling the depth-dependent CDR so as to include both the geometric response and the septal penetration and collimator scatter response. One is to fit a Gaussian plus exponential function that is rotationally invariant to the measured point source response at several source-detector distances. However, a rotationally-invariant exponential function cannot represent the star-shaped septal penetration tails in detail. Another is to perform Monte-Carlo (MC) simulations to generate the depth-dependent point spread functions (PSFs) for all necessary distances. However, MC simulations, which require careful modeling of the SPECT detector components, can be challenging and accurate results may not be available for all of the different SPECT scanners in clinics. In this paper, we propose an alternative approach to CDR modeling. We use a Gaussian function plus a 2-D B-spline PSF template and fit the model to measurements of an I-131 point source at several distances. The proposed PSF-template-based approach is nearly non-parametric, captures the characteristics of the septal penetration tails, and minimizes the difference between the fitted and measured CDR at the distances of interest. The new model is applied to I-131 SPECT reconstructions of experimental phantom measurements, a patient study, and a MC patient simulation study employing the XCAT phantom. The proposed model yields up to a 16.5 and 10.8% higher recovery coefficient compared to the results with the conventional Gaussian model and the Gaussian plus exponential model, respectively. -
dc.identifier.bibliographicCitation IEEE TRANSACTIONS ON MEDICAL IMAGING, v.32, no.2, pp.295 - 305 -
dc.identifier.doi 10.1109/TMI.2012.2225441 -
dc.identifier.issn 0278-0062 -
dc.identifier.scopusid 2-s2.0-84873291125 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/7983 -
dc.identifier.url http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84873291125 -
dc.identifier.wosid 000314367100015 -
dc.language 영어 -
dc.publisher IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC -
dc.title Correction for Collimator-Detector Response in SPECT Using Point Spread Function Template -
dc.type Article -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordAuthor B-spline point spread function template -
dc.subject.keywordAuthor collimator-detector response -
dc.subject.keywordAuthor I-131 quantitative SPECT -
dc.subject.keywordPlus MONTE-CARLO-SIMULATION -
dc.subject.keywordPlus ABSORBED DOSE CALCULATION -
dc.subject.keywordPlus MODEL-BASED
COMPENSATION
-
dc.subject.keywordPlus QUANTITATIVE SPECT -
dc.subject.keywordPlus RADIONUCLIDE THERAPY -
dc.subject.keywordPlus RECONSTRUCTION -
dc.subject.keywordPlus SCATTER -
dc.subject.keywordPlus IMPLEMENTATION -
dc.subject.keywordPlus CONTAMINATION -
dc.subject.keywordPlus IN-111SPECT -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.