File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

신흥주

Shin, Heungjoo
Micro/Nano Integrated Systems Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.conferencePlace GE -
dc.citation.conferencePlace Estrel Congress CenterBerlin -
dc.citation.endPage 1035 -
dc.citation.startPage 1033 -
dc.citation.title 20th International Conference on Solid-State Sensors, Actuators and Microsystems and Eurosensors XXXIII, TRANSDUCERS 2019 and EUROSENSORS XXXIII -
dc.contributor.author Sharma, Deepti -
dc.contributor.author Lee, Jongmin -
dc.contributor.author Shin, Heungjoo -
dc.date.accessioned 2024-02-01T00:08:07Z -
dc.date.available 2024-02-01T00:08:07Z -
dc.date.created 2019-10-01 -
dc.date.issued 2019-06-23 -
dc.description.abstract We report the development of an electrochemical redox cycling-based immunosensor using microchannel-integrated sandwich 3D triple electrode system. The triple electrodes consisting of a suspended carbon mesh and substrate-bound carbon interdigitated array (IDA) nanoelectrodes fabricated using C-MEMS. To complete an immunosensor a specific electrode was modified via the selective electrochemical reduction of aryl diazonium salts, and thus monoclonal antibody (mAb) could be immobilized on only suspended mesh electrode and the IDA electrodes were employed for the efficient redox-cycling of redox species (PAP/PQI). The microchannel integration facilitated 8-fold better low limit of detection (LOD) as compare to bulk, preventing diffusion of PAP to the bulk solution. © 2019 IEEE. -
dc.identifier.bibliographicCitation 20th International Conference on Solid-State Sensors, Actuators and Microsystems and Eurosensors XXXIII, TRANSDUCERS 2019 and EUROSENSORS XXXIII, pp.1033 - 1035 -
dc.identifier.doi 10.1109/TRANSDUCERS.2019.8808709 -
dc.identifier.scopusid 2-s2.0-85071947038 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/79622 -
dc.identifier.url https://ieeexplore.ieee.org/document/8808709 -
dc.language 영어 -
dc.publisher Institute of Electrical and Electronics Engineers Inc. -
dc.title Microchannel-Integrated Sandwich 3D Triple Electrodes for Enhanced Detection of Myoglobin as a Cardiac Biomarker -
dc.type Conference Paper -
dc.date.conferenceDate 2019-06-23 -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.