File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

박혜성

Park, Hyesung
Future Electronics and Energy Lab
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 455 -
dc.citation.number 4 -
dc.citation.startPage 447 -
dc.citation.title ASAIO JOURNAL -
dc.citation.volume 53 -
dc.contributor.author Gilbert, Richard J. -
dc.contributor.author Park, Hyesung -
dc.contributor.author Rasponi, Marco -
dc.contributor.author Redaelli, Alberto -
dc.contributor.author Gellman, Barry -
dc.contributor.author Dasse, Kurt A. -
dc.contributor.author Thorsen, Todd -
dc.date.accessioned 2023-12-22T09:12:39Z -
dc.date.available 2023-12-22T09:12:39Z -
dc.date.created 2014-10-07 -
dc.date.issued 2007-07 -
dc.description.abstract The development of microfluidic devices supporting physiological blood flow has the potential to yield biomedical technologies emulating human organ function. However, advances in this area have been constrained by the fact that artificial microchannels constructed for such devices need to achieve maximum chemical diffusion as well as hemocompatibility. To address this issue, we designed an elastomeric microfluidic flow device composed of poly (dimethylsiloxane) to emulate the geometry and flow properties of the pulmonary microcirculation. Our chip design is characterized by high aspect ratio (width > height) channels in an orthogonally interconnected configuration. Finite element simulations of blood flow through the network design chip demonstrated that the apparent pressure drop varied in a linear manner with flow rate. For simulated flow rates < 250 mu l min(-1), the simulated pressure drop was < 2000 Pa, the flow was laminar, and hemolysis was minimal. Hemolysis rate, assayed in terms of [total plasma hemoglobin (TPH) (sample - control)/(TPH control)] during 6 and 12 hour perfusions at 250 mu l/min, was < 5.0% through the entire period of device perfusion. There was no evidence of microscopic thrombus at any channel segment or junction under these perfusion conditions. We conclude that a microfluidic blood flow device possessing asymmetric and interconnected microchannels exhibits uniform flow properties and preliminary hemocompatibility. Such technology should foster the development of miniature oxygenators and similar biomedical devices requiring both a microscale reaction volume and physiological blood flow. -
dc.identifier.bibliographicCitation ASAIO JOURNAL, v.53, no.4, pp.447 - 455 -
dc.identifier.doi 10.1097/MAT.0b013e3180a5e8ab -
dc.identifier.issn 1058-2916 -
dc.identifier.scopusid 2-s2.0-34547679635 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/6990 -
dc.identifier.url https://insights.ovid.com/crossref?an=00002480-200707000-00009 -
dc.identifier.wosid 000248286600010 -
dc.language 영어 -
dc.publisher LIPPINCOTT WILLIAMS & WILKINS -
dc.title Computational and functional evaluation of a microfluidic blood flow device -
dc.type Article -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordPlus ON-A-CHIP -
dc.subject.keywordPlus IN-VITRO -
dc.subject.keywordPlus PULMONARY CAPILLARIES -
dc.subject.keywordPlus PLATELET DEPOSITION -
dc.subject.keywordPlus MEMBRANE SKELETON -
dc.subject.keywordPlus SOFT LITHOGRAPHY -
dc.subject.keywordPlus ARTIFICIAL LUNG -
dc.subject.keywordPlus FLUID-DYNAMICS -
dc.subject.keywordPlus WHOLE-BLOOD -
dc.subject.keywordPlus SIMULATION -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.