DC Field Value Language
dc.citation.endPage 52 -
dc.citation.number 5 -
dc.citation.startPage 44 -
dc.citation.title 한국유체기계학회 논문집 -
dc.citation.volume 26 -
dc.contributor.author 임도영 -
dc.contributor.author 방인철 -
dc.date.accessioned 2023-12-21T11:42:28Z -
dc.date.available 2023-12-21T11:42:28Z -
dc.date.created 2023-11-01 -
dc.date.issued 2023-10 -
dc.description.abstract This study presents the design and preliminary verification of URILO-II, an experimental facility developed for integral effect test of nuclear safety technologies, while also providing a platform for thermal-hydraulic training through experimentation and observation. URILO-II was modeled on the OPR1000 power plant, the most commonly operated in Korea, scaled down to 1/8 height and 1/10 diameter. The refrigerant R134a was utilized to simulate two-phase flow of OPR1000 under 26.5 bar pressure.
Scaling analysis indicated that similarity for the two-phase flow was secured, but distortion in single-phase flow heat transfer and temperature distribution was identified due to the refrigerant’s low single-phase heat transfer rate. Adjustments in power or flow rate were deemed necessary for accurate accident simulations. To check scaling design values, Comparative and CFD analyses were conducted, with resulted in an 8.5 % lower pressure drop. Further research will extend preliminary verification through system code analysis.
-
dc.identifier.bibliographicCitation 한국유체기계학회 논문집, v.26, no.5, pp.44 - 52 -
dc.identifier.doi 10.5293/kfma.2023.26.5.044 -
dc.identifier.issn 2287-9706 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/66077 -
dc.language 한국어 -
dc.publisher 한국유체기계학회 -
dc.title.alternative Scaling Design of Refrigerant-cooled Thermal-Hydraulic Integral Effect Test Facility for OPR1000 -
dc.title OPR1000 원전의 냉매 열수력 종합효과 실험장치 척도설계 -
dc.type Article -
dc.description.isOpenAccess FALSE -
dc.identifier.kciid ART003003800 -
dc.description.journalRegisteredClass kci -
dc.subject.keywordAuthor OPR1000(한국표준형원전) -
dc.subject.keywordAuthor Integral effect(종합효과) -
dc.subject.keywordAuthor Scaling(척도) -
dc.subject.keywordAuthor Refrigerant(냉매) -
dc.subject.keywordAuthor Two-phase flow(이상유동 -