File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

박수진

Park, Soojin
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 3889 -
dc.citation.number 16 -
dc.citation.startPage 3884 -
dc.citation.title ANALYTICAL CHEMISTRY -
dc.citation.volume 73 -
dc.contributor.author Lee, W -
dc.contributor.author Park, Soojin -
dc.contributor.author Chang, T -
dc.date.accessioned 2023-12-22T11:43:08Z -
dc.date.available 2023-12-22T11:43:08Z -
dc.date.created 2014-09-26 -
dc.date.issued 2001-08 -
dc.description.abstract Liquid chromatography at the chromatographic critical condition has drawn much attention as an attractive characterization method of block copolymers since it has been proposed that a part of a polymer chain becomes "chromatographically invisible" at this condition, which would permit the characterization of individual blocks. A critical condition for a polymer species has been commonly established by use of mixed-solvent systems. It is not easy, however, to reproduce the critical condition since the retention of polymers depends very sensitively on the solvent composition and purity. Furthermore, the preferential sorption of a component in a mixed solvent may cause an additional problem. Therefore, the use of a single solvent is highly desirable to improve the reproducibility as well as the repeatability. In this study, a single-solvent critical condition for polyisoprene was established with 1,4-dioxane and C18 bonded silica as the mobile and stationary phases, respectively. At this condition, the "chromatographic invisibility" of polystyrene-polyisoprene diblock copolymers was critically examined and it was found that a rigorous chromatographic invisibility was not achieved and the retention of the block copolymers was affected by the length of the blocks under the critical condition. Some other chromatographic applications using the single-solvent system are also reported. -
dc.identifier.bibliographicCitation ANALYTICAL CHEMISTRY, v.73, no.16, pp.3884 - 3889 -
dc.identifier.doi 10.1021/ac010072o -
dc.identifier.issn 0003-2700 -
dc.identifier.scopusid 2-s2.0-0035880580 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/6593 -
dc.identifier.url http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=0035880580 -
dc.identifier.wosid 000170482800013 -
dc.language 영어 -
dc.publisher AMER CHEMICAL SOC -
dc.title Liquid chromatography at the critical condition for polyisoprene using a single solvent -
dc.type Article -
dc.description.journalRegisteredClass scopus -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.