There are no files associated with this item.
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.citation.endPage | 198 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 191 | - |
dc.citation.title | JOURNAL OF CHROMATOGRAPHY A | - |
dc.citation.volume | 986 | - |
dc.contributor.author | Cho, D | - |
dc.contributor.author | Park, Soojin | - |
dc.contributor.author | Hong, J | - |
dc.contributor.author | Chang, T | - |
dc.date.accessioned | 2023-12-22T11:14:18Z | - |
dc.date.available | 2023-12-22T11:14:18Z | - |
dc.date.created | 2014-09-26 | - |
dc.date.issued | 2003-02 | - |
dc.description.abstract | The retention behavior of low- and high-molecular-mass poly(ethylene oxide) (PEO) in reversed-phase (RP) and normal-phase (NP) liquid chromatography was investigated. In RPLC using a C18 bonded silica stationary phase and an acetonitrile-water mixture mobile phase, the sorption process of PEO to the stationary phase showed ΔH°>0 and ΔS°>0. Therefore, PEO retention in RPLC separation is an energetically unfavorable, entropy-driven process, which results in an increase of PEO retention as the temperature increases. In addition, at the enthalpy-entropy compensation point the elution volume of PEO was very different from the column void volume. These observations are quite different from the RPLC retention behavior of many organic polymers. The peculiar retention behavior of PEO in RPLC separation can be understood in terms of the hydrophobic interaction of this class of typical amphiphilic compounds with the non-polar stationary phase, on the one hand, and with the aqueous mobile phase, on the other. The entropy gain due to the release of the solvated water molecules from the PEO chain and the stationary phase is believed to be responsible for the entropy-driven separation process. On the other hand, in NPLC using an amino-bonded silica stationary phase and an acetonitrile-water mixture mobile phase, PEO showed normal enthalpy-driven retention behavior: ΔH°<0 and ΔS°<0, with the retention decreasing with increasing temperature and PEO eluting near the column void volume at the enthalpy-entropy compensation point. Therefore, high-resolution temperature gradient NPLC separation of high-molecular-mass PEO samples can be achieved with relative ease. The molecular mass distribution of high-molecular-mass PEO was found to be much narrower than that measured by size-exclusion chromatography. | - |
dc.identifier.bibliographicCitation | JOURNAL OF CHROMATOGRAPHY A, v.986, no.2, pp.191 - 198 | - |
dc.identifier.doi | 10.1016/S0021-9673(02)01953-2 | - |
dc.identifier.issn | 0021-9673 | - |
dc.identifier.scopusid | 2-s2.0-0037423106 | - |
dc.identifier.uri | https://scholarworks.unist.ac.kr/handle/201301/6570 | - |
dc.identifier.url | http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=0037423106 | - |
dc.identifier.wosid | 000180764200003 | - |
dc.language | 영어 | - |
dc.publisher | ELSEVIER SCIENCE BV | - |
dc.title | Retention mechanism of poly(ethylene oxide) in reversed-phase and normal-phase liquid chromatography | - |
dc.type | Article | - |
dc.description.journalRegisteredClass | scopus | - |
Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.
Tel : 052-217-1404 / Email : scholarworks@unist.ac.kr
Copyright (c) 2023 by UNIST LIBRARY. All rights reserved.
ScholarWorks@UNIST was established as an OAK Project for the National Library of Korea.