File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

MitchellRobertJames

Mitchell, Robert J.
Applied and Environmental Microbiology Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 507 -
dc.citation.number 3 -
dc.citation.startPage 500 -
dc.citation.title BIOSENSORS & BIOELECTRONICS -
dc.citation.volume 21 -
dc.contributor.author Lee, JH -
dc.contributor.author Mitchell, Robert J. -
dc.contributor.author Kim, BC -
dc.contributor.author Cullen, DC -
dc.contributor.author Gu, MB -
dc.date.accessioned 2023-12-22T10:13:42Z -
dc.date.available 2023-12-22T10:13:42Z -
dc.date.created 2014-09-18 -
dc.date.issued 2005-09 -
dc.description.abstract In this study, a cell-based array technology that uses recombinant bioluminescent bacteria to detect and classify environmental toxicity has been implemented to develop two biosensor arrays, i.e., a chip and a plate array. Twenty recombinant bioluminescent bacteria, having different promoters fused with the bacterial lux genes, were immobilized within LB-agar. About 2 μl of the cell-agar mixture was deposited into the wells of either a cell chip or a 384-well plate. The bioluminescence (BL) from the cell arrays was measured with the use of highly sensitive cooled CCD camera that measured the bioluminescent signal from the immobilized cells and then quantified the pixel density using image analysis software. The responses from the cell arrays were characterized using three chemicals that cause either superoxide damage (paraquat), DNA damage (mitomycin C) or protein/membrane damage (salicylic acid). The responses were found to be dependent upon the promoter fused upstream of the lux operon within each strain. Therefore, a sample's toxicity can be analyzed and classified through the changes in the BL expression from each well. Moreover, a time of only 2 h was needed for analysis, making either of these arrays a fast, portable and economical high-throughput biosensor system for detecting environmental toxicities. -
dc.identifier.bibliographicCitation BIOSENSORS & BIOELECTRONICS, v.21, no.3, pp.500 - 507 -
dc.identifier.doi 10.1016/j.bios.2004.12.015 -
dc.identifier.issn 0956-5663 -
dc.identifier.scopusid 2-s2.0-23044515022 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/6261 -
dc.identifier.url http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=23044515022 -
dc.identifier.wosid 000232580300013 -
dc.language 영어 -
dc.publisher ELSEVIER ADVANCED TECHNOLOGY -
dc.title A cell array biosensor for environmental toxicity analysis -
dc.type Article -
dc.description.journalRegisteredClass scopus -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.