There are no files associated with this item.
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.citation.endPage | 507 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 500 | - |
dc.citation.title | BIOSENSORS & BIOELECTRONICS | - |
dc.citation.volume | 21 | - |
dc.contributor.author | Lee, JH | - |
dc.contributor.author | Mitchell, Robert J. | - |
dc.contributor.author | Kim, BC | - |
dc.contributor.author | Cullen, DC | - |
dc.contributor.author | Gu, MB | - |
dc.date.accessioned | 2023-12-22T10:13:42Z | - |
dc.date.available | 2023-12-22T10:13:42Z | - |
dc.date.created | 2014-09-18 | - |
dc.date.issued | 2005-09 | - |
dc.description.abstract | In this study, a cell-based array technology that uses recombinant bioluminescent bacteria to detect and classify environmental toxicity has been implemented to develop two biosensor arrays, i.e., a chip and a plate array. Twenty recombinant bioluminescent bacteria, having different promoters fused with the bacterial lux genes, were immobilized within LB-agar. About 2 μl of the cell-agar mixture was deposited into the wells of either a cell chip or a 384-well plate. The bioluminescence (BL) from the cell arrays was measured with the use of highly sensitive cooled CCD camera that measured the bioluminescent signal from the immobilized cells and then quantified the pixel density using image analysis software. The responses from the cell arrays were characterized using three chemicals that cause either superoxide damage (paraquat), DNA damage (mitomycin C) or protein/membrane damage (salicylic acid). The responses were found to be dependent upon the promoter fused upstream of the lux operon within each strain. Therefore, a sample's toxicity can be analyzed and classified through the changes in the BL expression from each well. Moreover, a time of only 2 h was needed for analysis, making either of these arrays a fast, portable and economical high-throughput biosensor system for detecting environmental toxicities. | - |
dc.identifier.bibliographicCitation | BIOSENSORS & BIOELECTRONICS, v.21, no.3, pp.500 - 507 | - |
dc.identifier.doi | 10.1016/j.bios.2004.12.015 | - |
dc.identifier.issn | 0956-5663 | - |
dc.identifier.scopusid | 2-s2.0-23044515022 | - |
dc.identifier.uri | https://scholarworks.unist.ac.kr/handle/201301/6261 | - |
dc.identifier.url | http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=23044515022 | - |
dc.identifier.wosid | 000232580300013 | - |
dc.language | 영어 | - |
dc.publisher | ELSEVIER ADVANCED TECHNOLOGY | - |
dc.title | A cell array biosensor for environmental toxicity analysis | - |
dc.type | Article | - |
dc.description.journalRegisteredClass | scopus | - |
Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.
Tel : 052-217-1404 / Email : scholarworks@unist.ac.kr
Copyright (c) 2023 by UNIST LIBRARY. All rights reserved.
ScholarWorks@UNIST was established as an OAK Project for the National Library of Korea.