File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

김희령

Kim, Hee Reyoung
RAdiation and MagnetohydroDynamics Advanced Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.startPage 110597 -
dc.citation.title APPLIED RADIATION AND ISOTOPES -
dc.citation.volume 192 -
dc.contributor.author Lee, Hyeonmin -
dc.contributor.author Sung, Si Hyeong -
dc.contributor.author Shin, Seung Hun -
dc.contributor.author Kim, Hee Reyoung -
dc.date.accessioned 2023-12-21T13:07:45Z -
dc.date.available 2023-12-21T13:07:45Z -
dc.date.created 2022-12-07 -
dc.date.issued 2023-02 -
dc.description.abstract In this study, Monte Carlo simulations were used to calculate the full-energy peak efficiency of a p-type coaxial high-purity germanium (HPGe) detector. The HPGe detector was modeled using MCNP6 and Geant4, and the thickness of the dead layer of germanium crystals was estimated for an accurate simulation. The dead layer was divided into front and side components, where a point source and a Marinelli beaker source were used to estimate each dead layer thickness. The model was validated by comparing the simulated as well as experimental results for the standard sources of cylindrical and Marinelli beakers. The Geant4 results and experimental results matched up to 4% in the 59.54–1836.05 keV energy range, while MCNP6 matched up to 6% when adjusted for coincidence summing effects. HPGe detector modeled in Monte Carlo simulations can be utilized for experimental validation and experimental setup prior to using actual HPGe detectors. -
dc.identifier.bibliographicCitation APPLIED RADIATION AND ISOTOPES, v.192, pp.110597 -
dc.identifier.doi 10.1016/j.apradiso.2022.110597 -
dc.identifier.issn 0969-8043 -
dc.identifier.scopusid 2-s2.0-85143712050 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/60078 -
dc.identifier.url https://www.sciencedirect.com/science/article/pii/S0969804322004821?via%3Dihub -
dc.identifier.wosid 000903958400002 -
dc.language 영어 -
dc.publisher Pergamon Press Ltd. -
dc.title Dead layer estimation of an HPGe detector using MCNP6 and Geant4 -
dc.type Article -
dc.description.isOpenAccess FALSE -
dc.relation.journalWebOfScienceCategory Chemistry, Inorganic & Nuclear;Nuclear Science & Technology;Radiology, Nuclear Medicine & Medical Imaging -
dc.relation.journalResearchArea Chemistry;Nuclear Science & Technology;Radiology, Nuclear Medicine & Medical Imaging -
dc.type.docType Article -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordAuthor Dead layer -
dc.subject.keywordAuthor Detection efficiency -
dc.subject.keywordAuthor HPGe -
dc.subject.keywordAuthor High-purity germanium detector -
dc.subject.keywordAuthor Monte Carlo simulation -
dc.subject.keywordPlus EFFICIENCY CALCULATION -
dc.subject.keywordPlus GERMANIUM DETECTORS -
dc.subject.keywordPlus CYLINDRICAL SOURCES -
dc.subject.keywordPlus PEAK EFFICIENCY -
dc.subject.keywordPlus CALIBRATION -
dc.subject.keywordPlus THICKNESS -
dc.subject.keywordPlus SIMULATION -
dc.subject.keywordPlus INCREASE -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.