File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

변영재

Bien, Franklin
BICDL
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 3798 -
dc.citation.number 9 -
dc.citation.startPage 3794 -
dc.citation.title IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS II-EXPRESS BRIEFS -
dc.citation.volume 69 -
dc.contributor.author Namgoong, Gyeongho -
dc.contributor.author Park, Hyunjun -
dc.contributor.author Bien, Franklin -
dc.date.accessioned 2023-12-21T13:41:34Z -
dc.date.available 2023-12-21T13:41:34Z -
dc.date.created 2022-09-19 -
dc.date.issued 2022-09 -
dc.description.abstract This brief presents a class-D power amplifier (PA) with an adaptive zero-voltage switching (A-ZVS) technique for 6.78 MHz resonant wireless power transfer (R-WPT) system. In R-WPT operation, the loading impedance of a PA can be varied by the process tolerance of the LC resonant components or WPT environments, such as the resonant topology, coupling coefficient, and loading condition of the receiver. In particular, the commonly used series-parallel resonant topology suffers from resonant point deviation of primary LC tank, resulting in hard switching of the PA. Consequently, efficiency degradation and electromagnetic interference can occur under multi-MHz operation. The proposed A-ZVS feedback loop calibrates the equivalent resonant capacitance in real-time to achieve ZVS by adjusting the loading impedance to be slightly inductive. The proposed PA was fully integrated except for one switched capacitor used as the tuning element and fabricated in a TSMC 0.18 p.m BCD process. The measurement results demonstrated robust ZVS operation with a peak system efficiency of 52.7 % and an enhanced maximum transmitting power of 107 %. -
dc.identifier.bibliographicCitation IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS II-EXPRESS BRIEFS, v.69, no.9, pp.3794 - 3798 -
dc.identifier.doi 10.1109/TCSII.2022.3179422 -
dc.identifier.issn 1549-7747 -
dc.identifier.scopusid 2-s2.0-85131726004 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/59717 -
dc.identifier.wosid 000848263100038 -
dc.language 영어 -
dc.publisher IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC -
dc.title A Real-Time Calibrated Adaptive-ZVS Class-D Power Amplifier for 6.78 MHz Wireless Power Transfer System -
dc.type Article -
dc.description.isOpenAccess FALSE -
dc.relation.journalWebOfScienceCategory Engineering, Electrical & Electronic -
dc.relation.journalResearchArea Engineering -
dc.type.docType Article -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordAuthor wireless power transfer -
dc.subject.keywordAuthor Adaptive zero-voltage switching (A-ZVS) -
dc.subject.keywordAuthor class-D power amplifier -
dc.subject.keywordAuthor PWM-controlled switched capacitor -
dc.subject.keywordPlus VOLTAGE -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.