File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)
Related Researcher

조윤경

Cho, Yoon-Kyoung
FRUITS Lab.
Read More

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 246 -
dc.citation.number 3 -
dc.citation.startPage 238 -
dc.citation.title MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS -
dc.citation.volume 12 -
dc.contributor.author Yoon, DS -
dc.contributor.author Cho, Yoon-Kyoung -
dc.contributor.author Oh, KW -
dc.contributor.author Kim, S -
dc.contributor.author Kim, YA -
dc.contributor.author Han, JI -
dc.contributor.author Lim, G -
dc.date.accessioned 2023-12-22T10:08:30Z -
dc.date.available 2023-12-22T10:08:30Z -
dc.date.created 2014-09-05 -
dc.date.issued 2006-02 -
dc.description.abstract We have fabricated a microfluidic gel valve device that used reversible sol-gel transition of methyl cellulose (MC). A microheater and a microtemperature sensor were implemented in each microchannel in the gel valve device. Before evaluating the performance of the gel valve device, various properties of the MC solution were investigated using viscometer, spectrophotometer, and NMR. Gelation temperature was increased as the MC concentration was increased. Clear gel, an intermediate state between clear sol and turbid gel, was found at the temperature range from 30-40°C to 50-60°C. Temperature at each microchannel of the device was measured and the effect of the temperature difference on the valve operation was elucidated. In order to have normal operation of the gel valve, it was important to keep the temperature of the heated microchannel around 60°C while keeping the temperature of the flowing microchannel below 35°C. The temperature difference between two microchannels was about 23 K when fan forced cooling (FFC) method was used. For normal performance of the gel valve device, a temporary pause of fluid flow for at least 5 s was required to complete the local gelation in the microchannel. Stable gel valve performance was obtained at the flow rates larger than 5 μl/min. The gel valve device showed no leakage up to 2.07×104 Pa. -
dc.identifier.bibliographicCitation MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, v.12, no.3, pp.238 - 246 -
dc.identifier.doi 10.1007/s00542-005-0051-5 -
dc.identifier.issn 0946-7076 -
dc.identifier.scopusid 2-s2.0-31144472416 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/5884 -
dc.identifier.url http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=31144472416 -
dc.identifier.wosid 000234875200007 -
dc.language 영어 -
dc.publisher SPRINGER -
dc.title A microfluidic gel valve device using reversible sol-gel transition of methyl cellulose for biomedical application -
dc.type Article -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordAuthor methyl cellulose -
dc.subject.keywordAuthor sol-gel -
dc.subject.keywordAuthor gel valve -
dc.subject.keywordAuthor BioMEMS -
dc.subject.keywordPlus POLYMERASE-CHAIN-REACTION -
dc.subject.keywordPlus GELATION -
dc.subject.keywordPlus METHYLCELLULOSE -
dc.subject.keywordPlus THERMOGELATION -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.