DC Field Value Language
dc.citation.endPage 356 -
dc.citation.number 4 -
dc.citation.startPage 349 -
dc.citation.title 한국수소및신에너지학회논문집 -
dc.citation.volume 27 -
dc.contributor.author 오현철 -
dc.date.accessioned 2023-12-21T23:15:50Z -
dc.date.available 2023-12-21T23:15:50Z -
dc.date.created 2022-03-16 -
dc.date.issued 2016-08 -
dc.description.abstract Volumetric capacity metrics at cryogenic condition are critical for technological and commercial development. It must be calculated and reported in a uniform and consistent manner to allow comparisons among different materials. In this paper, we propose a simple and universal protocol for the determination of volumetric capacity of sorbent materials at cryogenic condition. Usually, the sample container volume containing porous sample at RT can be directly determined by a helium expansion test. At cryogenic temperatures, however, this direct helium expansion test results in inaccurate values of the sample container volume for microporous materials due to a significant helium adsorption, resulting significant errors in hydrogen uptake. For reducing this container volume error, therefore, we introduced and applied the indirect method such as ‘volume correction using a non-porous material’, showing a reliable cold volume correction. -
dc.identifier.bibliographicCitation 한국수소및신에너지학회논문집, v.27, no.4, pp.349 - 356 -
dc.identifier.doi 10.7316/KHNES.2016.27.4.349 -
dc.identifier.issn 1738-7264 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/57837 -
dc.identifier.url http://koreascience.or.kr/article/JAKO201627038924104.page -
dc.language 한국어 -
dc.publisher 한국수소및신에너지학회 -
dc.title.alternative Volumetric Hydrogen Sorbent Measurement at High Pressure and Cryogenic Condition - Basic Measurement Protocols -
dc.title 부피법을 이용한 고압․극저온 수소 흡착량측정 방식의 기본 원리 -
dc.type Article -
dc.description.isOpenAccess FALSE -
dc.identifier.kciid ART002139449 -
dc.description.journalRegisteredClass kci -
dc.subject.keywordAuthor Sieverts apparatus(시버트 타입 부피측정 장치) -
dc.subject.keywordAuthor Hydrogen storage(수소저장) -
dc.subject.keywordAuthor PCT(압력-조성-온도 선) -
dc.subject.keywordAuthor Cold volume correction(극저온 부피 보정) -