DC Field Value Language
dc.citation.endPage 341 -
dc.citation.number 5 -
dc.citation.startPage 336 -
dc.citation.title Korean Journal of Materials Research -
dc.citation.volume 29 -
dc.contributor.author Park, Jawoo -
dc.contributor.author Oh, Hyunchul -
dc.date.accessioned 2023-12-21T19:08:51Z -
dc.date.available 2023-12-21T19:08:51Z -
dc.date.created 2022-03-16 -
dc.date.issued 2019-05 -
dc.description.abstract The gas adsorption isotherm requires accurate measurement for the analysis of porous materials and is used as an index of surface area, pore distribution, and adsorption amount of gas. Basically, adsorption isotherms of porous materials are measured conventionally at 77K and 87K using liquid nitrogen and liquid argon. The cold volume calibration in this conventional method is done simply by splitting a sample cell into two zones (cold and warm volumes) by controlling the level sensor in a Dewar filled with liquid nitrogen or argon. As a result, BET measurement for textural properties is mainly limited to liquefied gases (i.e. N2 or Ar) at atmospheric pressure. In order to independently investigate other gases (e.g. hydrogen isotopes) at cryogenic temperature, a novel temperature control system in the sample cell is required, and consequently cold volume calibration at various temperatures becomes more important. In this study, a cryocooler system is installed in a commercially available BET device to control the sample cell temperature, and the automated cold volume calibration method of temperature variation is introduced. This developed calibration method presents a reliable and reproducible method of cryogenic measurement for hydrogen isotope separation in porous materials, and also provides large flexibility for evaluating various other gases at various temperature. © Materials Research Society of Korea. -
dc.identifier.bibliographicCitation Korean Journal of Materials Research, v.29, no.5, pp.336 - 341 -
dc.identifier.doi 10.3740/mrsk.2019.29.5.336 -
dc.identifier.issn 1225-0562 -
dc.identifier.scopusid 2-s2.0-85066819867 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/57807 -
dc.identifier.url http://journal.mrs-k.or.kr/journal/article.php?code=66833 -
dc.language 영어 -
dc.publisher The Materials Research Society of Korea -
dc.title.alternative 극저온(20K) 수소동위원소 흡착 등온선의 온도 변화에 대한 자동 저온 부피 교정 -
dc.title Automated Cold Volume Calibration of Temperature Variation in Cryogenic Hydrogen Isotope Sorption Isotherm -
dc.type Article -
dc.description.isOpenAccess FALSE -
dc.type.docType Article -
dc.description.journalRegisteredClass scopus -
dc.subject.keywordAuthor Accuracy -
dc.subject.keywordAuthor Adsorption isotherm -
dc.subject.keywordAuthor Calibration method -
dc.subject.keywordAuthor Cold volume and temperature calibrations -
dc.subject.keywordAuthor Cryogenic measurements -