File Download

There are no files associated with this item.

  • Find it @ UNIST can give you direct access to the published full text of this article. (UNISTARs only)

Views & Downloads

Detailed Information

Cited time in webofscience Cited time in scopus
Metadata Downloads

Full metadata record

DC Field Value Language
dc.citation.endPage 1130 -
dc.citation.number 5 -
dc.citation.startPage 1121 -
dc.citation.title ENDOCRINOLOGY AND METABOLISM -
dc.citation.volume 36 -
dc.contributor.author Kim, Ki-Hun -
dc.contributor.author Lee, Juhui -
dc.contributor.author Ahn, Chang Ho -
dc.contributor.author Yu, Hyeong Won -
dc.contributor.author Choi, June Young -
dc.contributor.author Lee, Ho-Young -
dc.contributor.author Lee, Won Woo -
dc.contributor.author Moon, Jae Hoon -
dc.date.accessioned 2023-12-21T15:09:18Z -
dc.date.available 2023-12-21T15:09:18Z -
dc.date.created 2022-01-12 -
dc.date.issued 2021-10 -
dc.description.abstract Background: Heart rate (HR) monitored by a wearable device (WD) has demonstrated its clinical feasibility for thyrotoxicosis subjects. However, the association of HR monitored by wearables with hypothyroidism has not been examined. We assessed the association between serum thyroid hormone concentration and three WD-HR parameters in hypothyroid subjects. Methods: Forty-four subjects scheduled for radioactive iodine therapy (RAI Tx) after thyroid cancer surgery were included. Thirty subjects were prepared for RAI Tx by thyroid hormone withdrawal (hypothyroidism group) and 14 subjects by recombinant human thyrotropin (control group). Three WD-HR parameters were calculated from the HR data collected during rest, during sleep, and from 2:00 AM to 6:00 AM, respectively. We analyzed the changes in conventionally measured resting HR (On-site rHR) and WDHR parameters relative to thyroid hormone levels. Results: Serum free thyroxine (T4) levels, On-site rHR, and WD-HR parameters were lower in the hypothyroid group than in the control group at the time of RAI Tx. WD-HR parameters also reflected minute changes in free T4 levels. A decrease in On-site rHR and WD-HR parameters by one standard deviation (On-site rHR, approximately 12 bpm; WD-HR parameters, approximately 8 bpm) was associated with a 0.2 ng/dL decrease in free T4 levels (P<0.01) and a 2-fold increase of the odds ratio of hypothyroidism (P<0.01). WD-HR parameters displayed a better goodness-of-fit measure (lower quasi-information criterion value) than On-site rHR in predicting the hypothyroidism. Conclusion: This study identified WD-HR parameters as informative and easy-to-measure biomarkers to predict hypothyroidism. -
dc.identifier.bibliographicCitation ENDOCRINOLOGY AND METABOLISM, v.36, no.5, pp.1121 - 1130 -
dc.identifier.doi 10.3803/EnM.2021.1216 -
dc.identifier.issn 2093-596X -
dc.identifier.scopusid 2-s2.0-85119282778 -
dc.identifier.uri https://scholarworks.unist.ac.kr/handle/201301/56593 -
dc.identifier.url https://www.e-enm.org/journal/view.php?doi=10.3803/EnM.2021.1216 -
dc.identifier.wosid 000727577100020 -
dc.language 영어 -
dc.publisher KOREAN ENDOCRINE SOC -
dc.title Association between Thyroid Function and Heart Rate Moni tored by Wearable Devices in Patients with Hypothyroidism -
dc.type Article -
dc.description.isOpenAccess FALSE -
dc.relation.journalWebOfScienceCategory Endocrinology & Metabolism -
dc.relation.journalResearchArea Endocrinology & Metabolism -
dc.type.docType Article -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.description.journalRegisteredClass kci -
dc.subject.keywordAuthor Wearable electronic devices -
dc.subject.keywordAuthor Hypothyroidism -
dc.subject.keywordAuthor Heart rate -

qrcode

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.